3.1.4.2 DC Power Connection
The Switch uses a single ETB series terminal block plug with four pins which allows you to connect
up to two separate power supplies. If one power supply fails the system can operate on the
remaining power supply. Use two wires to connect to a single terminal pair, one wire for the positive
terminal and one wire for the negative terminal.
Note: The current rating of the power wires must be greater than 20 Amps. The power
supply to which the Switch connects must have a built-in circuit breaker or switch
to toggle the power.
Note: When installing the power wire, push it wire firmly into the terminal as deep as
possible and make sure that no exposed (bare) wire can be seen or touched.
Exposed power wire is dangerous. Use extreme care when connecting a
DC power source to the device.
To connect a power supply:
1
Use a screwdriver to loosen the terminal block captive screws.
2
Connect one end of a power wire to the Switch’s RTN (return) pin and tighten the captive screw.
3
Connect the other end of the power wire to the positive terminal on the power supply.
4
Connect one end of a power wire to the Switch’s -48V (input) pin and tighten the captive screw.
5
Connect the other end of the power wire to the negative terminal on the power supply.
6
Insert the terminal block plug in the Switch’s terminal block header.
3.1.5 Signal Slot
The Signal slot (fitted with the signal connector) allows you to connect devices to the Switch, such
as sensors or other ZyXEL switches which support the external alarm feature. This feature is in
addition to the system alarm, which detects abnormal temperatures, and voltage levels on the
Switch.
Your Switch can respond to an external signal in four ways.
• The ALM LED shows an alert.
• The Signal slot can send an external alarm on to another device. By daisy-chaining the signal
sensor cables from one Switch to another ZyXEL switch which supports this feature, the external
alarm alert (but not the system alarm) is received on each Switch.
• The Switch can be configured to send an SNMP trap to the SNMP server. See
for more information on using SNMP.
• The Switch can be configured to create an error log of the alarm. See
for more information on using the system log.
3.1.5.1 Connect a Sensor to the Signal Slot
This section shows you how to connect an external sensor device to the Switch.
Содержание MES3500-24
Страница 2: ......
Страница 6: ...Safety Warnings MES3500 24 24F User s Guide 6...
Страница 20: ...Table of Contents MES3500 24 24F User s Guide 20...
Страница 21: ...21 PART I User s Guide...
Страница 22: ...22...
Страница 47: ...Chapter 4 The Web Configurator MES3500 24 24F User s Guide 47...
Страница 48: ...Chapter 4 The Web Configurator MES3500 24 24F User s Guide 48...
Страница 78: ...Chapter 6 Tutorials MES3500 24 24F User s Guide 78...
Страница 79: ...79 PART II Technical Reference...
Страница 80: ...80...
Страница 240: ...Chapter 28 VLAN Mapping MES3500 24 24F User s Guide 240...
Страница 264: ...Chapter 33 Private VLAN MES3500 24 24F User s Guide 264...
Страница 282: ...Chapter 36 DHCP MES3500 24 24F User s Guide 282...
Страница 336: ...Appendix A Common Services MES3500 24 24F User s Guide 336...