Chapter 8 Basic Setting
MES3500-24/24F User’s Guide
96
Speed/Duplex
Select the speed and the duplex mode of the Ethernet connection on this port. Choices are
Auto, 10M/Half Duplex, 10M/Full Duplex, 100M/Half Duplex, 100M/Full Duplex and
1000M/Full Duplex (Gigabit connections only).
Selecting Auto (auto-negotiation) allows one port to negotiate with a peer port automatically
to obtain the connection speed and duplex mode that both ends support. When auto-
negotiation is turned on, a port on the Switch negotiates with the peer automatically to
determine the connection speed and duplex mode. If the peer port does not support auto-
negotiation or turns off this feature, the Switch determines the connection speed by
detecting the signal on the cable and using half duplex mode. When the Switch’s auto-
negotiation is turned off, a port uses the pre-configured speed and duplex mode when
making a connection, thus requiring you to make sure that the settings of the peer port are
the same in order to connect.
Flow Control
A concentration of traffic on a port decreases port bandwidth and overflows buffer memory
causing packet discards and frame losses. Flow Control is used to regulate transmission of
signals to match the bandwidth of the receiving port.
The Switch uses IEEE802.3x flow control in full duplex mode and backpressure flow control in
half duplex mode.
IEEE802.3x flow control is used in full duplex mode to send a pause signal to the sending
port, causing it to temporarily stop sending signals when the receiving port memory buffers
fill.
Back Pressure flow control is typically used in half duplex mode to send a "collision" signal to
the sending port (mimicking a state of packet collision) causing the sending port to
temporarily stop sending signals and resend later. Select Flow Control to enable it.
802.1p
Priority
This priority value is added to incoming frames without a (802.1p) priority queue tag. See
Priority Queue Assignment in
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Table 13
Basic Setting > Port Setup (continued)
LABEL
DESCRIPTION
Содержание MES3500-24
Страница 2: ......
Страница 6: ...Safety Warnings MES3500 24 24F User s Guide 6...
Страница 20: ...Table of Contents MES3500 24 24F User s Guide 20...
Страница 21: ...21 PART I User s Guide...
Страница 22: ...22...
Страница 47: ...Chapter 4 The Web Configurator MES3500 24 24F User s Guide 47...
Страница 48: ...Chapter 4 The Web Configurator MES3500 24 24F User s Guide 48...
Страница 78: ...Chapter 6 Tutorials MES3500 24 24F User s Guide 78...
Страница 79: ...79 PART II Technical Reference...
Страница 80: ...80...
Страница 240: ...Chapter 28 VLAN Mapping MES3500 24 24F User s Guide 240...
Страница 264: ...Chapter 33 Private VLAN MES3500 24 24F User s Guide 264...
Страница 282: ...Chapter 36 DHCP MES3500 24 24F User s Guide 282...
Страница 336: ...Appendix A Common Services MES3500 24 24F User s Guide 336...