CONTENTS
This package contains a number of ancillary parts in addition to the CNXIRP.
These parts include:
IR Mask.
Two-Sided Tape.
If after reviewing these instructions you still have additional questions, please
contact a Crestron technical support representative in your area by dialing
one of the following numbers:
* In the US and Canada, call Crestron's corporate headquarters at
1-888-CRESTRON [1-888-273-7876] or 1-201-767-3400.
* In Europe, call Crestron International at +32-15-50-99-50.
* In Asia, call Crestron Asia at +852-2341-2016.
* In Latin America, call Crestron Latin America at +525-574-15-90.
For local support from exclusive Crestron factory-trained personnel call:
* In Australia, call Soundcorp at +613-941-61066.
* In New Zealand, call Amber Technologies at +649-410-8382.
INSTALLATION
ATTACHING THE CNXIRP TO IR SENSOR WINDOWS (See A below)
1. Identify the clear adhesive layer on the flat bottom surface of the
CNXIRP shell.
2. Peel off the protective cover and affix the CNXIRP to the center of the
IR sensor window on the controlled component's front panel.
3. In some cases it may be difficult to find the location of the IR sensor on
the component. Consult the owner's manual of the unit, or the manufacturer,
for the exact IR window location.
4. If the CNXIRP shell must be removed and repositioned for any reason,
it may be necessary to replace the adhesive with a new piece of the two-
sided tape (supplied) to restore adhesion.
INSTALLING THE IR MASK (See B above)
The IR mask (supplied) is designed to fit over the CNXIRP shell, (shown
in B above), so that the sensor window of the controlled component is
completely covered. It prevents unwanted external IR signals from
passing through or leaking past it. It also prevents emitting IR from the
CNXIRP shell from radiating backward into the IR sensors of other nearby
components.
1. Without removing the adhesive backing from the CNXIRP shell or IR
mask, fit the two pieces together and accurately position them over the
IR sensor window of the component to be controlled.
2. If necessary, neatly trim the IR mask being sure that it overlaps the
extremities of the component's IR sensor window.
3. Remove the adhesive backing from the CNXIRP shell and IR mask and
position them over the IR sensor window while pressing down firmly.
DESCRIPTION
The CNXIRP, shown below, contains an infrared (IR) LED housed in a miniature,
mouse shaped, black, injection molded plastic shell. The CNXIRP shell emits
IR control signals sent to it by a Crestron control system. The shell can be
installed directly on the IR sensor window of the controlled device or at a
nearby suitable location.
CONTENTS
This package contains a number of ancillary parts in addition to the CNXIRP.
These parts include:
IR Mask.
Two-Sided Tape.
If after reviewing these instructions you still have additional questions, please
contact a Crestron technical support representative in your area by dialing
one of the following numbers:
* In the US and Canada, call Crestron's corporate headquarters at
1-888-CRESTRON [1-888-273-7876] or 1-201-767-3400.
* In Europe, call Crestron International at +32-15-50-99-50.
* In Asia, call Crestron Asia at +852-2341-2016.
* In Latin America, call Crestron Latin America at +525-574-15-90.
For local support from exclusive Crestron factory-trained personnel call:
* In Australia, call Soundcorp at +613-941-61066.
* In New Zealand, call Amber Technologies at +649-410-8382.
INSTALLATION
ATTACHING THE CNXIRP TO IR SENSOR WINDOWS (See A below)
1. Identify the clear adhesive layer on the flat bottom surface of the
CNXIRP shell.
2. Peel off the protective cover and affix the CNXIRP to the center of the
IR sensor window on the controlled component's front panel.
3. In some cases it may be difficult to find the location of the IR sensor on
the component. Consult the owner's manual of the unit, or the manufacturer,
for the exact IR window location.
4. If the CNXIRP shell must be removed and repositioned for any reason,
it may be necessary to replace the adhesive with a new piece of the two-
sided tape (supplied) to restore adhesion.
INSTALLING THE IR MASK (See B above)
The IR mask (supplied) is designed to fit over the CNXIRP shell, (shown
in B above), so that the sensor window of the controlled component is
completely covered. It prevents unwanted external IR signals from
passing through or leaking past it. It also prevents emitting IR from the
CNXIRP shell from radiating backward into the IR sensors of other nearby
components.
1. Without removing the adhesive backing from the CNXIRP shell or IR
mask, fit the two pieces together and accurately position them over the
IR sensor window of the component to be controlled.
2. If necessary, neatly trim the IR mask being sure that it overlaps the
extremities of the component's IR sensor window.
3. Remove the adhesive backing from the CNXIRP shell and IR mask and
position them over the IR sensor window while pressing down firmly.
DESCRIPTION
The CNXIRP, shown below, contains an infrared (IR) LED housed in a miniature,
mouse shaped, black, injection molded plastic shell. The CNXIRP shell emits
IR control signals sent to it by a Crestron control system. The shell can be
installed directly on the IR sensor window of the controlled device or at a
nearby suitable location.
CRESTRON
CNXIRP
Cresnet Infrared Emitter
NOTE: White striped
side is positive (+)
2-pin
connector
7 FT
3 FT
9/16”
Top View
Side View
1/4”
5/16”
Adhesive Layer
Side View
IR
Mask
CNXIRP
Shell
B
CNXIRP
Shell
Internal
IR Emitter
High
Output
Side
Low
Output
Side
Mini-wire
lead
Clear adhesive layer.
(Replace, if necessary,
with a short piece of the
two-sided tape supplied).
A
CRESTRON
CNXIRP
Cresnet Infrared Emitter
NOTE: White striped
side is positive (+)
2-pin
connector
7 FT
3 FT
9/16”
Top View
Side View
1/4”
5/16”
Adhesive Layer
Side View
IR
Mask
CNXIRP
Shell
B
CNXIRP
Shell
Internal
IR Emitter
High
Output
Side
Low
Output
Side
Mini-wire
lead
Clear adhesive layer.
(Replace, if necessary,
with a short piece of the
two-sided tape supplied).
A