IES-1248-51 User’s Guide
144
Chapter 18 xDSL Line Data
18.3 xDSL Line Data Screen
This
screen displays an ADSL port’s line bit allocation.
ATUC/ATUR ES
The Number of Errored Seconds transmitted (downstream) or received
(upstream) on this ADSL port.
ATUC/ATUR SES
The Number of Severely Errored Seconds transmitted (downstream) or received
(upstream) on this ADSL port. Severely errored seconds contained 30% or more
errored blocks or at least one defect. This is a subset of the
Down/Up Stream
ES
.
ATUC/ATUR UAS
The downstream or upstream number of UnAvailable Seconds.
Fast FEBE
In fast mode, the number of Far End Block Errors (Far End Cyclic Redundancy
Checks).
Fast NEBE
In fast mode, the number of Near End Block Errors (Near End Cyclic
Redundancy Checks).
Fast FEFEC
In fast mode, the Far End number of ADSL frames repaired by Forward Error
Correction.
Fast NEFEC
In fast mode, the Near End number of ADSL frames repaired by Forward Error
Correction.
Interleaved FEBE
In interleaved mode, the number of Far End Block Errors (Far End Cyclic
Redundancy Checks).
Interleaved NEBE
In interleaved mode, the number of Near End Block Errors (Near End Cyclic
Redundancy Checks).
Interleaved FEFEC
In interleaved mode, the Far End number of ADSL frames repaired by Forward
Error Correction.
Interleaved NEFEC
In interleaved mode, the Near End number of ADSL frames repaired by Forward
Error Correction.
LPR
This is the number of times that the subscriber’s ADSL device has experienced a
Loss of Power (been off).
15 min, 1day history This section of the screen displays line performance statistics for the current and
previous 15-minute periods, as well as for the current and previous 24 hours.
lofs
The number of Loss Of Frame Seconds that have occurred within the period.
loss
The number of Loss Of Signal Seconds that have occurred within the period.
lols
The number of Loss Of Link Seconds that have occurred within the period.
lprs
The number of Loss of Power Seconds that have occurred within the period.
es
The number of Errored Seconds that have occurred within the period.
init
The number of successful initializations that have occurred within the period.
ses
The number of Severely Errored Seconds that have occurred within the period.
uas
The number of UnAvailable Seconds that have occurred within the period.
Table 27
xDSL Performance (continued)
LABEL
DESCRIPTION
Содержание IES-1248-51
Страница 1: ...IES 1248 51 ADSL2 IP DSLAM User s Guide Version 3 51 ABQ 1 3 2006 ...
Страница 4: ...IES 1248 51 User s Guide 4 Interference Statements and Warnings ...
Страница 22: ...IES 1248 51 User s Guide 22 Table of Contents Index 379 ...
Страница 30: ...IES 1248 51 User s Guide 30 List of Figures ...
Страница 34: ...IES 1248 51 User s Guide 34 List of Tables ...
Страница 47: ...IES 1248 51 User s Guide Chapter 2 Hardware Installation 47 Figure 6 IES 1248 51 Frame Ground Frame Ground ...
Страница 48: ...IES 1248 51 User s Guide 48 Chapter 2 Hardware Installation ...
Страница 62: ...IES 1248 51 User s Guide 62 Chapter 4 MDF Connections ...
Страница 73: ...IES 1248 51 User s Guide Chapter 7 Introducing the Web Configurator 73 Figure 29 Logout ...
Страница 74: ...IES 1248 51 User s Guide 74 Chapter 7 Introducing the Web Configurator ...
Страница 88: ...IES 1248 51 User s Guide 88 Chapter 9 Home and Port Statistics Screens ...
Страница 90: ...IES 1248 51 User s Guide 90 Chapter 10 System Information Figure 44 System Info ...
Страница 98: ...IES 1248 51 User s Guide 98 Chapter 12 User Account ...
Страница 104: ...IES 1248 51 User s Guide 104 Chapter 13 Switch Setup ...
Страница 106: ...IES 1248 51 User s Guide 106 Chapter 14 IP Setup ...
Страница 126: ...IES 1248 51 User s Guide 126 Chapter 16 xDSL Port Setup ...
Страница 140: ...IES 1248 51 User s Guide 140 Chapter 17 xDSL Profiles Setup ...
Страница 154: ...IES 1248 51 User s Guide 154 Chapter 19 VLAN ...
Страница 188: ...IES 1248 51 User s Guide 188 Chapter 28 2684 Routed Mode ...
Страница 192: ...IES 1248 51 User s Guide 192 Chapter 30 Syslog ...
Страница 210: ...IES 1248 51 User s Guide 210 Chapter 33 Alarm ...
Страница 240: ...IES 1248 51 User s Guide 240 Chapter 38 Commands ...
Страница 256: ...IES 1248 51 User s Guide 256 Chapter 40 Alarm Commands ...
Страница 262: ...IES 1248 51 User s Guide 262 Chapter 41 DHCP Relay Commands ...
Страница 282: ...IES 1248 51 User s Guide 282 Chapter 44 IGMP Commands ...
Страница 286: ...IES 1248 51 User s Guide 286 Chapter 45 Packet Filter Commands ...
Страница 292: ...IES 1248 51 User s Guide 292 Chapter 46 IP Commands ...
Страница 302: ...IES 1248 51 User s Guide 302 Chapter 48 SNMP ...
Страница 338: ...IES 1248 51 User s Guide 338 Chapter 49 ADSL Commands ...
Страница 358: ...IES 1248 51 User s Guide 358 Chapter 50 Virtual Channel Management ...
Страница 370: ...IES 1248 51 User s Guide 370 Chapter 51 Troubleshooting ...
Страница 378: ...IES 1248 51 User s Guide 378 ...