ZXR10 2900 Series User Manual
Command
Function
zte(cfg)#
set ethernet-oam port
<
portlist
>
link-monitor symbol-period
threshold
<
1-65535
>
window
<
1-65535
>
This configures the
symbol period event
which is used for link
monitor.
The symbol period is decided by the symbol number which is
received during a specified period by switch, that is, a period
is to collect a specified number of symbols. When the error
symbol number is larger than the period receiving threshold,
the link alarm will be appeared.
The parameter
threshold
<
1-65535
>: the error symbol col-
lected in a period. It is 1 by default.
The parameter
window
<
1-65535
>: the symbol number pe-
riod. The unit is million. For example, 30 represents that col-
lecting 30,000,000 symbols is a period. It is 1 by default.
8. To configure the error frame, use the following command.
Command
Function
zte(cfg)#
set ethernet-oam port
<
portlist
>
link-monitor frame
threshold
<
1-65535
>
window
<
1-60
>
This configures the
error frame.
The parameter
threshold
<
1-65535
>: the number of error
frame. The default value is 1.
The parameter
window
<
1-60
>: time period. The default
value is 1 second.
9. To configure the period of error frame, use the following com-
mand.
Command
Function
zte(cfg)#
set ethernet-oam port
<
portlist
>
link-monitor frame-period
threshold
<
1-65535
>
window
<
1-600000
>
This configures the
period of error frame.
The frame period is decided by the frame number which is re-
ceived during a specified period by switch, that is, a period is
to collect a specified number of frames. When the error frame
number is larger than the period receiving threshold, the link
alarm will be appeared.
The parameter
threshold
<
1-65535
>: the error frame num-
ber, the default is 1.
The parameter
window
<
1-600000
>: the frame number, the
default value is 100. the unit is thousand. 1 represents 1000.
10. To configure error frame summary, use the following com-
mand.
188