For the selection of the antifreeze fluid, please refer to the following table.
For the selection of the antifreeze fluid, please refer to the following table.
Am
Am bi
bi ent
ent tem
tem per
per atu
atu re
re
Ab
Ab ov
ov e -25ºC
e -25ºC
Ab
Ab ov
ov e -40ºC
e -40ºC
Antifreeze fluid
Antifreeze fluid
-25ºC antifreeze fluid
-25ºC antifreeze fluid
-40ºC antifreeze fluid
-40ºC antifreeze fluid
–
–
Operating methods
Operating methods
The rocker switch has two gear positions. When the switch is in the 1
The rocker switch has two gear positions. When the switch is in the 1
st
st
gear position,
gear position,
only the water pump works; when it is in the 2
only the water pump works; when it is in the 2
nd
nd
gear position, both the water pump and
gear position, both the water pump and
heater work. At this time, the fan
heater work. At this time, the fan speed switch is turned on
speed switch is turned on to blow out wa
to blow out warm air.
rm air.
COOL制冷
COOL制冷
HIGH高
HIGH高
MIDDLE中
MIDDLE中
LOW低
LOW低
关
关
OFF
OFF
关
关
OFF
OFF
通风
通风
VENTILATE
VENTILATE
制冷
制冷
COOL
COOL
Fig. 06 – 05
Fig. 06 – 05
When t
When the wate
he water out
r outlet t
let temperat
emperature r
ure reaches
eaches 80
80
, the
, the heater
heater stops
stops heatin
heating
g
℃
℃
and the
and the
contro
control lig
l light of t
ht of the swi
he switch go
tch goes out.
es out. When the
When the water t
water tempera
emperature i
ture is lower
s lower than 65
than 65
, the
, the
℃
℃
heater will work again. The above operations will repeat in cycles.
heater will work again. The above operations will repeat in cycles.
When the heater is used for the first time in cold seasons, first check the heater
When the heater is used for the first time in cold seasons, first check the heater
condition to ensure there is no foreign matters blocked in the air passage, the heater
condition to ensure there is no foreign matters blocked in the air passage, the heater
rotates freely, the combustion-supporting air inlet and the exhaust gas outlet are not
rotates freely, the combustion-supporting air inlet and the exhaust gas outlet are not
blocked with clay etc. and air intake & air exhaust are smooth.
blocked with clay etc. and air intake & air exhaust are smooth.
When the heater does not need to be used, the switch should be turned off. Meanwhile,
When the heater does not need to be used, the switch should be turned off. Meanwhile,
the power control light goes out and the heater stops burning. But at this time, control
the power control light goes out and the heater stops burning. But at this time, control
light of the switch doesn’t go out immediately and is off about 3 minutes
light of the switch doesn’t go out immediately and is off about 3 minutes
The vehicle power is forbidden to be switched off when the control lights are on,
The vehicle power is forbidden to be switched off when the control lights are on,
otherwi
otherwi se hea
se heat insi
t insi de the heate
de the heater can’t b
r can’t b e dispersed and the heater will fail.
e dispersed and the heater will fail.
Caution
Caution
Содержание QY30V
Страница 8: ......
Страница 10: ......
Страница 36: ......
Страница 56: ......
Страница 94: ......
Страница 144: ...04 49 04 49 Operation crane superstructure Operation crane superstructure Fig 04 40 Fig 04 40...
Страница 146: ......
Страница 156: ...05 9 05 9...
Страница 158: ......
Страница 170: ......
Страница 202: ......
Страница 242: ...08 39 08 39 M60 M60 66 66 1008 1008 1418 1418...
Страница 244: ......
Страница 272: ...09 27 09 27...
Страница 274: ......