12、REAR COVER COMPONENT
110
CHK
ADJ
NO.
PART NO.
PART NAME
QTY
CAUTION
1
1224200-176000 Colloid battery electric device box upper cover
1
2
1184200-024000 ZT310
-
R Side bracket relay
1
G8HN-1C4T-RJ
3
1184100-017000 ZT250
-
S EFI relay
3
KH-1A4T
1050954-019000 MT05.2 Engine Controller - Model ZT310-RC4
Delphi EFI
1050954-037000 MSE6.0 Controller-ZT180MN
Bosch EFI
5
1184100-010000 ZT250-S Start relay
1
6
1184200-016000 ZT310 PKE buzzer
1
7
1240300-007000 HJ125
-
6 Battery rubber gasket
3
Electrical component (colloid battery)
Fig. 13 REAR COVER
COMPONENT
4
1
PROCEDURE:
●
Relay
Remove the colloid battery electric device box upper cover (1).
Pull up the cable and unplug the side stand relay (2) and the EFI relay (3).
Turn off the positive and negative.
protective rubber caps (red for the positive and black for the negative) of the starter relay (5). Remove the
positive and negative connectors by unscrewing the nut, and screw the nut back onto the relay stud to prevent
loss.
Find the starting relay and main cable connector unplugged.
●
Engine Control Unit
(
ECU
)
Delphi EFI: Hold the ECU (4) connector in the direction of the arrow and separate the ECU (4) from the main
cable.
Bosch EFI: Urn the switch on ECU
⑷
in the direction of the arrow and pull it out to separate ECU
⑷
from the
main cable.
●
Fuse box
Fuse box cover with corresponding instructions.
●
PKE buzzer
Remove the PKE buzzer (6). Clean up the remaining offset.
CAUTION:
●
Starting from July 10, 2020, all ECUs need to add battery pads, as shown
in the upper left picture.
Bosch EFI
Delphi EFI