manualshive.com logo in svg
background image

19 

3.3 Recycling the product 

 

Your appliance has reached the end of its working life

. You would like to dispose of it or replace it. 

Please do not throw it into your dustbin or into your local selective sorting containers. 

 

When this symbol appears on a new appliance, it means that the equipment must not 

be thrown away and that it will be collected selectively so that it can be reused, 

recycled or recovered. Any substances it may contain which are potentially dangerous 

to the environment will be eliminated or neutralised. 

 

You can give it to a community association which will be able to repair it and put it back into circulation. 

If you buy a new appliance, you can take the old one back to the reseller or ask the transporter to take it 

back. 

This is known as a “

One-for-One

” exchange. 

Otherwise please take it to a waste collection centre, if your local council has set up a selective 

collection system for these products. 

 

 
 
 
 

 

 

 

 

3.4 EC compliance certificate 

Z.P.C.E. declares that the products or ranges below: 

SPECIAL POOL DEHUMIDIFIERS 

Sirocco 55-80-110 ambient and can be inset 

 

are in compliance with the provisions of the: 

 

 ELECTROMAGNETIC COMPATIBILITY directive 89/336/EEC. 

 

 LOW VOLTAGE directive 73/23/EEC, as amended by 93/068/EEC. 

 

The following harmonised standards have been applied: 

EN 60335.2.40 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

In the context of ongoing improvement, our products are subject to change without notice.      

Version 02/2010 

Give the appliance 

to a community 

association.

 

Take the used device back 

to the reseller when 

making a new purchase. 

 

Take the used 

device to a waste 
collection centre. 

 

Содержание SIROCCO 110

Страница 1: ...Installation instructions Air dehumidifier for indoor swimming pools R f N D 005 A EN Ver 02 2010 SIROCCO 55 80 110...

Страница 2: ...to surrounding air 6 1 3 5 Inset connection 7 1 3 6 Connection of the condensation drainage 8 1 3 7 Electric connections 8 1 3 8 Connection of the options 12 1 4 Commissioning 13 1 4 1 Starting the a...

Страница 3: ...on studs x4 dowel x 2 long bolt x 2 For Sirocco can be inset sleeve x 2 frame with cadre suction grid and filter x 1 frame with blowing grid frame fixture kit x 1 The appliance must be transported upr...

Страница 4: ...0 unit protection class Sirocco ambient IP 44 Sirocco can be inset IP 45 class I refrigerant gas R407C refrigerant charge see product information plate 1 2 2 Operating conditions operating range 10 C...

Страница 5: ...installed outside volumes 0 1 and 2 the appliance has a protection index of at least IP X5 In volume 2 see figures 702A and 702B the appliances must be either class II for lighting or class I protecte...

Страница 6: ...hat the materials used are compatible with a swimming pool environment the walls are sufficiently waterproofed and insulated to avoid condensation forming in the room when relative humidity reaches 60...

Страница 7: ...with two bolt screws washers and plugs supplied in a solid wall Pool minimum distance Sirocco 55 80 110 suction grid blowing grid Hygro Control condensation drainage air renewal system see 1 3 2 fres...

Страница 8: ...leeves and mark the two inside anchoring points install the fixing plugs into the solid wall using the marks present the appliance again and from the inside screw in the bolt screws washers into each...

Страница 9: ...7 3 Cable sizes Supply cable size for cables of a maximum length of 20 metres calculation basis 5A mm this must be checked and adapted depending on installation conditions Option Voltage Nominal powe...

Страница 10: ...echnician must install the device cables If the power cable is damaged it must be replaced by a qualified technician or by a Zodiac Pool Care Europe service station Main supply see 1 3 7 3 Regulation...

Страница 11: ...desired relative humidity Display of the ambient temperature and or humidity by pressing once C and or RH blink To exit press or wait 10 seconds only if your appliance is fitted with the hot water ba...

Страница 12: ...ll the digits light or and the appliance starts up Parameter setting in hygro thermostat or hygrostat mode Hygro Control must be on standby press and for 3 seconds hygro thermostat mode press or to se...

Страница 13: ...nput to the hot water battery 45 C minimum 90 C maximum Maximum pressure water battery circuit 3 bars Power returned to the air at 27 C input to the hot water battery Connection to the primary circuit...

Страница 14: ...s a heating request is active This safety device has two levels of triggering 1 by THS safety thermostat if the T C is 65 C it is automatically reset 2 if the temperature continues to increase the sec...

Страница 15: ...e thermostat function request active if 6Vac 50Hz between 2 and 4 8 input 12Vac 50Hz fan heat fault shunted not active fault active if 0Vac 50Hz between 8 and 4 d faut thermique ventilateur led lit up...

Страница 16: ...emperature than 5 C or than 40 C a defrosting cycle is in progress temperature is 5 C The compressor is stopped and ventilation is maintained the defrosting sensor is out of order The defrosting cycle...

Страница 17: ...ol and make a shunt between terminals 1 5 7 and check the voltage between 4 5 12V Replace the ECP 600 no yes Replace the Hygro Control See faults table 2 1 The appliance does not work No fault display...

Страница 18: ...o Is the appliance being ventilated all the time Voltage on the compressor terminals 230V or 400V yes Replace the contactor no no Re connect the Hygro Control and check that it is operational Wait for...

Страница 19: ...teries evaporator condenser and hot water by removing the cover from the appliance switched off Depending on the condition clean with a silk brush and a vacuum cleaner 3 2 Spare parts Naming Item numb...

Страница 20: ...e back to the reseller or ask the transporter to take it back This is known as a One for One exchange Otherwise please take it to a waste collection centre if your local council has set up a selective...

Страница 21: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 22: ...1 Electric diagram Sirocco 55 80 110 single phase...

Страница 23: ...2 Sirocco 110 three phase...

Страница 24: ...y 230Vac 50Hz for battery circulator or used for electric logic of the heating option by electric backing E1 high pressure switch E2 low pressure switch OAE back up heating option R heating resistor T...

Страница 25: ...4 Dimensions weight without option A B C Kg mm Sirocco 55 65 1030 620 653 Sirocco 80 75 1220 810 843 Sirocco 110 85 1410 1000 1033...

Страница 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 28: ...Care Europe Boulevard de la Romanerie BP 90023 49180 Saint Barth l my d Anjou cedex France www zodiac poolcare com Global provider of innovative pool products and services Produits et services innova...

Отзывы: