manualshive.com logo in svg
background image

10 

 

 

 

 

Technical specifications 

 

Admissible room temperature 

°C 0-55 

Admissible humidity level 

0-90 

Voltage 

V AC 

12 

Maximum voltage 

V AC 

24 

Protection index 

IP 20 

Dimensions: width / height / depth 

mm 

120 x 70 x 28 

Hysteresis 

Hymidity 

% 4 

temperature 

°C 1 

 

Display 

 
 

 

 
 

 

 

 

Hygro Control display 

Hygro-thermostat 

Hygrostat 

Thermostat 

On standby 

 

Active 

 

 

 

 

Starting up and stopping the appliance 

Press  

for 5 seconds. 

 

Locking/unlocking the keyboard 

To lock and unlock the keyboard:  

-  Hygro Control must be 

active,

 

- press  

 and  

 simultaneously for 3 seconds,  

- the 

 message is displayed or is removed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

By default: display of the temperature and/or desired relative humidity. 

Display of the ambient temperature and/or humidity by pressing 

 once, 

°C

 and/or 

%RH

 blink. To exit, press  

, or wait 10 seconds. 

*only if your appliance is fitted with the hot water battery option, or extra electric 
heating. 

- The 

numbering

 of the terminals must be respected, 

Do not put these cables into the same duct as other 230 V or 400 V to avoid any 

risk of interference of the signals,

 

Obstruct

 the place where the cable emerges from the wall or seal it by using materials 

other than

 silicone and silicone-based materials,

 in order to avoid any arrival of air 

exterior to the room through the duct or dividing wall. 

Main supply 12Vac-50Hz- between terminals 4 and 5. 

Temperature display* 

Relative Humidity 

Degree Fahrenheit 

Degree Celsius 

Requesting 
dehumidification 

Requesting heating 

EN 

Содержание SIROCCO 110

Страница 1: ...Installation instructions Air dehumidifier for indoor swimming pools R f N D 005 A EN Ver 02 2010 SIROCCO 55 80 110...

Страница 2: ...to surrounding air 6 1 3 5 Inset connection 7 1 3 6 Connection of the condensation drainage 8 1 3 7 Electric connections 8 1 3 8 Connection of the options 12 1 4 Commissioning 13 1 4 1 Starting the a...

Страница 3: ...on studs x4 dowel x 2 long bolt x 2 For Sirocco can be inset sleeve x 2 frame with cadre suction grid and filter x 1 frame with blowing grid frame fixture kit x 1 The appliance must be transported upr...

Страница 4: ...0 unit protection class Sirocco ambient IP 44 Sirocco can be inset IP 45 class I refrigerant gas R407C refrigerant charge see product information plate 1 2 2 Operating conditions operating range 10 C...

Страница 5: ...installed outside volumes 0 1 and 2 the appliance has a protection index of at least IP X5 In volume 2 see figures 702A and 702B the appliances must be either class II for lighting or class I protecte...

Страница 6: ...hat the materials used are compatible with a swimming pool environment the walls are sufficiently waterproofed and insulated to avoid condensation forming in the room when relative humidity reaches 60...

Страница 7: ...with two bolt screws washers and plugs supplied in a solid wall Pool minimum distance Sirocco 55 80 110 suction grid blowing grid Hygro Control condensation drainage air renewal system see 1 3 2 fres...

Страница 8: ...leeves and mark the two inside anchoring points install the fixing plugs into the solid wall using the marks present the appliance again and from the inside screw in the bolt screws washers into each...

Страница 9: ...7 3 Cable sizes Supply cable size for cables of a maximum length of 20 metres calculation basis 5A mm this must be checked and adapted depending on installation conditions Option Voltage Nominal powe...

Страница 10: ...echnician must install the device cables If the power cable is damaged it must be replaced by a qualified technician or by a Zodiac Pool Care Europe service station Main supply see 1 3 7 3 Regulation...

Страница 11: ...desired relative humidity Display of the ambient temperature and or humidity by pressing once C and or RH blink To exit press or wait 10 seconds only if your appliance is fitted with the hot water ba...

Страница 12: ...ll the digits light or and the appliance starts up Parameter setting in hygro thermostat or hygrostat mode Hygro Control must be on standby press and for 3 seconds hygro thermostat mode press or to se...

Страница 13: ...nput to the hot water battery 45 C minimum 90 C maximum Maximum pressure water battery circuit 3 bars Power returned to the air at 27 C input to the hot water battery Connection to the primary circuit...

Страница 14: ...s a heating request is active This safety device has two levels of triggering 1 by THS safety thermostat if the T C is 65 C it is automatically reset 2 if the temperature continues to increase the sec...

Страница 15: ...e thermostat function request active if 6Vac 50Hz between 2 and 4 8 input 12Vac 50Hz fan heat fault shunted not active fault active if 0Vac 50Hz between 8 and 4 d faut thermique ventilateur led lit up...

Страница 16: ...emperature than 5 C or than 40 C a defrosting cycle is in progress temperature is 5 C The compressor is stopped and ventilation is maintained the defrosting sensor is out of order The defrosting cycle...

Страница 17: ...ol and make a shunt between terminals 1 5 7 and check the voltage between 4 5 12V Replace the ECP 600 no yes Replace the Hygro Control See faults table 2 1 The appliance does not work No fault display...

Страница 18: ...o Is the appliance being ventilated all the time Voltage on the compressor terminals 230V or 400V yes Replace the contactor no no Re connect the Hygro Control and check that it is operational Wait for...

Страница 19: ...teries evaporator condenser and hot water by removing the cover from the appliance switched off Depending on the condition clean with a silk brush and a vacuum cleaner 3 2 Spare parts Naming Item numb...

Страница 20: ...e back to the reseller or ask the transporter to take it back This is known as a One for One exchange Otherwise please take it to a waste collection centre if your local council has set up a selective...

Страница 21: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 22: ...1 Electric diagram Sirocco 55 80 110 single phase...

Страница 23: ...2 Sirocco 110 three phase...

Страница 24: ...y 230Vac 50Hz for battery circulator or used for electric logic of the heating option by electric backing E1 high pressure switch E2 low pressure switch OAE back up heating option R heating resistor T...

Страница 25: ...4 Dimensions weight without option A B C Kg mm Sirocco 55 65 1030 620 653 Sirocco 80 75 1220 810 843 Sirocco 110 85 1410 1000 1033...

Страница 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 28: ...Care Europe Boulevard de la Romanerie BP 90023 49180 Saint Barth l my d Anjou cedex France www zodiac poolcare com Global provider of innovative pool products and services Produits et services innova...

Отзывы: