background image

11

❶ Installation

  

1.1 I  Selecting the location

•  When  the  appliance  is  installed  and  protected  by  a  residual  current  device  (RCD)  with  a 

maximum amperage of 30 mA, it should be installed at a distance of at least 2 metres from the 

edge of the pool.

•  If no RCD is installed with the appliance, it should be installed at a distance of at least 3.5 

metres from the edge of the pool. 

•  Do not lift the appliance by the body; use its base.

• 

Installation is only permitted outdoors: provide for a clear space around the appliance as shown in the diagram under 

§ "1.2 I  Hydraulic connections".

• 

Place the appliance on its anti-vibration blocks (supplied with the appliance, height adjustable) on a stable, solid and 

level surface, 

• 

This surface must be able to bear the weight (see § "5.2 I Technical specifications") of the appliance (in particular in 

the case of installation on a roof, a balcony or any other support).  

: Front

: Rear

: Anti-vibration pads

View of the appliance base from below for installing the anti-vibration blocks

The appliance must not be installed: 

• 

With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than 4 metres away, 

• 

Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),

• 

Near a heat source or flammable gas, 

• 

Near high-frequency equipment,

• 

In a location where it would be subject to snow build-up,

• 

In a location where it might be flooded by the condensates produced by the appliance when operating.

Tip: reduce any noise annoyance from your heat pump

•  Do not install it under or towards a window. 

• 

Do not tilt it towards your neighbours. 

• 

Install it in an open space (sound waves are reflected on surfaces).

• 

Install an acoustic screen around the heat pump, respecting the distances (see drawing § "1.2 I 

Hydraulic connections").

• 

Install 50 cm of flexible PVC pipe at the heat pump water inlet and outlet to absorb vibrations. 

EN

Содержание PM40 Series

Страница 1: ...H0686400_REVA 2020 02 More documents on www zodiac com PM40 Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ......

Страница 3: ...nsible for their safety Children must be supervised to ensure that they do not play with the appliance This appliance must not be used by children under 8 or by adults whose reduced physical sensoryor...

Страница 4: ...t separation in all poles allowing for complete disconnection in the event of category III overvoltage the instructions shall specify that disconnection means must be integrated into the fixed wiring...

Страница 5: ...EU 517 2014 In order to comply with the applicable standards and regulations in terms of the environment and installation in particular French decree No 2015 1790 and or European regulation EU 517 201...

Страница 6: ...where the appliance is equipped with the optional pressure gauge The high pressure circuit pipes are made of copper and have a diameter equal to or greater than 1 5 8 A certificate as indicated in 2...

Страница 7: ...orming any maintenance task check that the area is open and well ventilated Suitable ventilation must be provided throughout the maintenance task to allow any refrigerant that could be released into t...

Страница 8: ...of the cable glands etc Make sure that the appliance is properly fixed Make sure that the seals or insulating materials are not deteriorated to the point that they no longer prevent a flammable atmos...

Страница 9: ...to take account of the product s flammability The following procedure must be followed remove the refrigerant purge the circuit with an inert gas optional for A2L drain optional for A2L purge with an...

Страница 10: ...ocated on the scales before starting recovery operations 7 Start the recovery unit and operate as per its instructions 8 Do not overfill the cylinders no more than 80 of the volume must be filled with...

Страница 11: ...have any doubts contact the manufacturer The recovered refrigerant must be sent to the refrigerant supplier in its recovery cylinder with a waste transfer note Do not mix different refrigerants in th...

Страница 12: ...to contact your retailer Write down your retailer s contact details to help you find them more easily and fill in the product information on the back of the manual your retailer will ask you for this...

Страница 13: ...llation on a roof a balcony or any other support Front Rear Anti vibration pads View of the appliance base from below for installing the anti vibration blocks The appliance must not be installed With...

Страница 14: ...o work on the appliance Water inlet valve By pass valve Water outlet valve Water inlet adjustment valve optional Water outlet adjustment valve optional Water treatment system To evacuate the condensat...

Страница 15: ...in the country where it is installed The appliance is provided for connection to a general power supply with a TT or TN S neutral regime Electrical protection by circuit breaker with a suitable dedic...

Страница 16: ...liance The cables used for the options and the power cord must be kept separate risk of interference using a collar inside the appliance just after the glands 1 5 1 Heating priority option This functi...

Страница 17: ...ater circulation to continuous operation 24 7 To maintain the temperature throughout the season run automatic circulation for the equivalent of the water temperature divided by two the longer this tim...

Страница 18: ...outlet adjustment valve optional An incorrect by pass setting may cause the heat pump to malfunction Check that the hydraulic connections are correctly tightened and that there are no leaks Check tha...

Страница 19: ...hes between HEATING and COOLING mode in order to keep the pool at the temperature setpoint 2 C Example When the temperature setpoint is 28 C if the water temperature rises to 30 C the heat pump will a...

Страница 20: ...onfirm the hours setting Once the hours have been confirmed the minutes begin to flash Set the minutes using the or keys Press to confirm the start time setting and proceed to setting the stop time in...

Страница 21: ...appliance you must cut the electricity supply as there is a risk of electric shock which may cause material damage serious injury or even death It is recommended that the appliance undergo general se...

Страница 22: ...ow below 8 C The appliance is smoking The machine has come to the end of the defrost cycle water has changed to gaseous state and passes through the grid If your heat pump is not in its defrost cycle...

Страница 23: ...erature too low Send the pump to the retailer for a detailed inspection E3 Faulty water flowmeter Flowmeter incorrectly positioned Re make the connections Insufficient water flow Increase the water fl...

Страница 24: ...l vous pla t quiper l ext rieur A C contacteur appropri Water pump Pompe eau High Pressure switch Pressostat haute pression Low Pressure switch Pressostat basse pression Water Flow switch D tecteur de...

Страница 25: ...ous pla t quiper l ext rieur A C contacteur appropri Water pump Pompe eau High Pressure switch Pressostat haute pression Low Pressure switch Pressostat basse pression Water Flow switch D tecteur de d...

Страница 26: ...per l ext rieur A C contacteur appropri Water pump Pompe eau High Pressure switch Pressostat haute pression Low Pressure switch Pressostat basse pression Water Flow switch D tecteur de d bit d eau Pow...

Страница 27: ...pla t quiper l ext rieur A C contacteur appropri Water pump Pompe eau High Pressure switch Pressostat haute pression Low Pressure switch Pressostat basse pression Water Flow switch D tecteur de d bit...

Страница 28: ...pla t quiper l ext rieur A C contacteur appropri Water pump Pompe eau High Pressure switch Pressostat haute pression Low Pressure switch Pressostat basse pression Water Flow switch D tecteur de d bit...

Страница 29: ...pecifications 5 1 I Description A PM40 B 1 5 PVC connectors C Anti vibration pads D Winterising cover Heating priority E Remote control kit F PAC NET cleaning product Included Available as an accessor...

Страница 30: ...e m h 2 3 3 4 6 5 8 6 9 7 10 7 11 7 11 9 13 19 Refrigerant type R32 R410A R32 R410A Refrigerant load kg 0 4 0 75 0 9 1 1 1 15 1 5 2 5 1 25 1 45 2 8 CO2 equivalent 0 27 teq CO2 0 5 teq CO2 0 60 teq CO2...

Страница 31: ...J K L J Rear PM40 MD1 MD2 MD3 MD4 MD5 MD7 MD8 TD7 TD8 TD12 F 798 958 1015 1015 1070 1070 1077 1070 1077 1077 G 293 360 370 370 416 416 446 416 446 446 H 511 581 621 621 708 708 958 708 958 1258 I 279...

Страница 32: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...