5.2 I Technical specifications
PM40
MD1
MD2
MD3
MD4
MD5
MD7
MD8
TD7
TD8
TD12
Operating
temperatures
air
-8 to 38 °C
water
8 to 40 °C
Power output*
kW
4.7
7.5
10.5
11.7
14.7
17.7
22.5
18.5
22.1
32
Voltage
220-240V / 50 Hz / 1PH
380-415V / 50 Hz / 3PH
Admissible variation in voltage
± 10 %
Pollution class**
I
Pollution degree**
2
Overvoltage category**
II
Protection fuse
A
10
16
20
25
16
Heating: Maximum
electric current
requirement
A
5.15
7.94
10.7
12.25
13.11
16.19
19.3
7.63
8.24
12.1
Cooling: Maximum
electric current
requirement
A
4.92
8.77
10.45
11.35
12.25
16.19
19.3
7.87
8.78
14.5
Minimum cable
size**
mm²
3 x 1.5
3 x 2.5
3 x 4
5 x 2.5
5 x 4
3G1.5
3G2.5
3G4
5G2.5
5G4
Maximum discharge/
suction pressure
bar
42/15
Head loss
bar
10
12
14
16
30
Water flow rate
m³/h
2-3
3
4-6
5-8
6-9
7-10
7-11
7-11
9
13-19
Refrigerant type
R32
R410A
R32
R410A
Refrigerant load
kg
0.4
0.75
0.9
1.1
1.15
1.5
2.5
1.25
1.45
2.8
CO
2
equivalent
0.27 teq
CO
2
0.5 teq
CO
2
0.60 teq
CO
2
0.74 teq
CO
2
0.77 teq
CO
2
3.132
teq CO
2
5.220
teq CO
2
0.84 teq
CO
2
0.98 teq
CO
2
5.84 teq
CO
2
Approximate weight
kg
48
65
74
80
96
118
133
110
125
163
Appliance must have a protection rating (IP) IPX4 or above. Please read the label showing the protection rating IP for
your product.
* Performance levels: air at 28°C/water at 28°C/humidity at 80%.
** These specifications have been determined based on the requirements defined in standards IEC/EN 60335-1 and IEC/EN 60035-2-40 on the safety
of electrical appliances for household and similar purposes.
*** Values provided for information purposes for a maximum length of 20 metres (calculation base: NFC15-100), must be checked and adapted to