background image

11

  

3.3 I  Operation

• 

To prevent against any risk of explosion that may cause material damage, serious injury or 

even death, make sure that the hydraulic circuit is free of any debris or blockage and is not 

subject to excessive pressure, and that the filter cover is properly positioned and tightened.

• 

Ensure that all valves are open and/or that the power of the filtration pump is suitable for the 

size of the filter if the initial pressure is greater than 1.2 bar (17 psi).

• 

Never change the position of the multiway valve when the filter pump is in operation. 

• 

Never dismantle the valve when the filter is pressurised.

• 

Check:  

 

- the correct tightening of the hydraulic connectors,

 

- the stability of the filter, which must be level,

 

- that the hydraulic circuit is drained and does not contain any debris,

 

- that the filter cover is closed properly,

 

- that the valves are open.

• 

Open the filter isolation valves and the drain valve to the evacuation.

• 

Open the filter cover air bleed screw.

• 

Set the multiway valve to position "backwash".

•  Start the pump.

• 

When the filter level is at maximum (water comes out of the air bleed screw), close the cover air bleed screw.

• 

Check that there are no leaks on the hydraulic circuit.

• 

When starting for the first time, stay in position "backwash" until the water is clear in the transparent window on the 

side of the multiway valve.

• 

Stop the water circulation.

• 

Set the valve to position "rinse" and switch on the water circulation until the water is clear.

• 

Stop the filtration pump.

• 

Set the multiway valve to position "filter" and start a normal filtration cycle.

• 

Record the initial filter pressure shown on the pressure gauge to serve as reference value.

• 

Make sure that the pressure indicated lies within the operating range (see 

§"1.2 I  Technical specifications"

).

Tip: installation with a variable speed pump

• 

For an installation with a variable speed pump, it is normal to have a low initial pressure if the filtering 

speed is low, and vice versa. In such a case, always use the same filtering speed as a comparison reference.

Tip: to save water

• 

To consume less water, stop the washing and rinsing procedure as soon as the water is no longer cloudy 

in the transparent window on the side of the multiway valve.

Содержание MS FILTER D470

Страница 1: ...H0648400_REVB 2018 09 More documents on www zodiac poolcare com Instructions for installation and use English Filter Translation of the original instructions in French EN...

Страница 2: ...roperty or serious injuries possibly causing death All equipment even postage and packing paid travels at the risks and perils of the recipient The latter shall issue reserves in writing on the carrie...

Страница 3: ...with the appliance Failure to do so may result in material damage or serious or fatal injury and will void the warranty Keep these instructions for future reference for operation and maintenance work...

Страница 4: ...D800 D950 Filtering area m 0 16 0 20 0 32 0 47 0 66 Filter media capacity on kg Sand 0 4 0 8 mm 85 100 160 310 485 Thick glass 1 0 3 0 mm 15 15 30 45 60 Thin glass 0 7 1 3 mm 60 75 105 225 345 Flow r...

Страница 5: ...ers Drain plug Base Tank Automatic air release Dimension in mm D470 D530 D650 D800 D950 Clearance below valve 310 320 375 390 420 A 340 350 405 430 460 B 465 475 530 660 690 C 529 539 594 736 766 D 70...

Страница 6: ...ng lodged in the pipes and with the fewest obstacles possible bends other appliances to avoid head loss Place on a stable level and solid surface e g concrete floor Secure the filter to the ground usi...

Страница 7: ...air release onto the large threaded orifice of the T connector Tip installing the bleed screw The bleed screw already contains its own seal do not use Teflon tape to seal Screw the pressure gauge ont...

Страница 8: ...ion of the filter Pass a nut around the bent pipe then position the assembly without bonding in this step see image Gently tighten the nut and firmly tighten the nut to obtain perfect alignment betwee...

Страница 9: ...nifold and its strainers Level the filter media as it is poured in Then pour in the fine grain filter media up to the required level See the label on the filter for the amounts of filter media to use...

Страница 10: ...to the filter media and returned to the pool Pool suction open Pool discharge open Filter inlet or outlet open Discharge to the drainage system closed Position Backwash The filter media is backflushed...

Страница 11: ...ilter and sent directly to the pool Pool suction open Pool discharge open Filter inlet or outlet closed Discharge to the drainage system closed Position Closed Water no longer circulates in the multiw...

Страница 12: ...ion backwash Start the pump When the filter level is at maximum water comes out of the air bleed screw close the cover air bleed screw Check that there are no leaks on the hydraulic circuit When start...

Страница 13: ...in When the water appears clear through the transparent window on the side of the multiway valve switch off the filter pump Set the valve to the rinse position and switch the filtration system back on...

Страница 14: ...level see 2 2 3 Filling the filter Replace the damaged manifold and or manifold strainers The pressure gauge needle shakes violently Air leak in the circuit Suction valves half closed Check the connec...

Страница 15: ......

Страница 16: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...

Отзывы: