5
❷ Installation
2.1 I Selecting the location
•
The filter must be installed:
- after the circulation pump (see image ),
- before the heating and/or water treatment system (see image ),
- ideally 0.5 metres below the water level (see image
:
),
- ideally less than 5 metres from the pool (see image
:
),
- in a dry ventilated equipment room protected against frost.
•
The filter must not be installed:
- in an area subject to flooding, splashing, rain or exposed to direct sunlight,
- more than 1.5 metres above the water level (see image
:
),
- near a heat source or source of flammable gas,
- in an equipment room where chemicals are stored, since the emanations could damage the filter.
•
Easy access is required for maintenance work (cover, hydraulic connection, valves, draining).
•
The hydraulic circuit before the filter must be as short as possible to prevent air pockets from becoming lodged in the
pipes, and with the fewest obstacles possible (bends, other appliances), to avoid head loss.
•
Place on a stable, level and solid surface (e.g. concrete floor).
•
Secure the filter to the ground using stainless steel screws (not included).
•
Check that the filter is installed more than 1.5 metres from the pool switch box (see image
:
) in order to be able
to stay clear when turning on.
•
We strongly recommend fitting a check valve if the filter is installed above the water level.
•
Installation of valves upstream and downstream from the filter is mandatory if it is installed below the water level.
: Pump
: Filter
: Heating system
: Water treatment system
: Suction valves (suction outlets valves,
skimmers, suction ports)
: Discharge valve to the pool
: Drainage valve to the drainage system
: Filter
: Pool water Level
: Ideal distance from the filter relative to
the water level (0.5 m)
: Maximum distance above the water level
(1.5 M)
: Ideal distance from the pool
(between 0.4 and 5 m)
: Minimum compulsory distance between
the filter and any switch box (1.5 m)