background image

12

❹ Maintenance

  

4.1 I  Winterizing

• 

Stop the water circulation.

• 

Clean the filter (see 

§4.1.2 Backflushing

).

• 

Drain the water out of the filter (see 

§4.1.3 Replacing the filter media

), and the entire hydraulic circuit.

• 

If the filter is positioned below the water level, close the isolation valves at suction and discharge.

• 

Turn the lever of the multiway valve to an intermediate position (between any 2 settings) to preserve the internal 

gasket.

  

4.2 I  Maintenance

4.1.1 User maintenance

• 

Clean the outside of the appliance, do not use solvent-based products.

• 

Check the filter pressure and the condition of the pressure gauge and the air release once a week.

• 

Remove debris from the pump's pre-filter basket (see pump manual).

• 

Check that there are no leaks in the hydraulic circuit.

4.1.2 Backflushing

• 

Stop the filter pump and make sure to switch off your water treatment appliance if any, since water will not flow in 

this part of the hydraulic circuit.

• 

Check that the pressure shown on the pressure gauge is 0 bar.

• 

Set the valve to position "backwash" and switch on the filter pump again.

• 

When the water appears clear through the transparent window on the side of the multiway valve, switch off the filter 

pump.

• 

Set the valve to the "rinse" position and switch the filtration system back on.

• 

When the water appears clear through the transparent window on the side of the multiway valve, switch off the filter 

pump.

• 

Set the valve to the "filter" position and switch the filter pump back on.

Tip: backflushing

• 

Quickly switch back and forth between the "backwash" and "rinse" positions in order to unclog and more 

easily clean the filter medium. This process reduces water consumption.

• 

Backflush when water circulation becomes more difficult (pressure more than 0.3 to 0.5 bar above normal 

pressure, in the yellow or red area of the pressure gauge).

• 

Backflushing is recommended once a month.

4.1.3 Replacing the filter media

• 

Stop the water circulation.

• 

Set the valve to position "closed" and close the other valves as a precaution.

• 

Open the air bleed screw on the cover and unscrew the drain plug to drain the water from the filter.

• 

Take off the cover then remove the filter media manually or using a water and dust vacuum cleaner (take care not to 

damage the diffuser, the manifold and its strainers).

• 

Fill the filter with new filter media (see 

§2.2.3 Filling the filter

).

EN

Содержание MS FILTER D470

Страница 1: ...H0648400_REVB 2018 09 More documents on www zodiac poolcare com Instructions for installation and use English Filter Translation of the original instructions in French EN...

Страница 2: ...roperty or serious injuries possibly causing death All equipment even postage and packing paid travels at the risks and perils of the recipient The latter shall issue reserves in writing on the carrie...

Страница 3: ...with the appliance Failure to do so may result in material damage or serious or fatal injury and will void the warranty Keep these instructions for future reference for operation and maintenance work...

Страница 4: ...D800 D950 Filtering area m 0 16 0 20 0 32 0 47 0 66 Filter media capacity on kg Sand 0 4 0 8 mm 85 100 160 310 485 Thick glass 1 0 3 0 mm 15 15 30 45 60 Thin glass 0 7 1 3 mm 60 75 105 225 345 Flow r...

Страница 5: ...ers Drain plug Base Tank Automatic air release Dimension in mm D470 D530 D650 D800 D950 Clearance below valve 310 320 375 390 420 A 340 350 405 430 460 B 465 475 530 660 690 C 529 539 594 736 766 D 70...

Страница 6: ...ng lodged in the pipes and with the fewest obstacles possible bends other appliances to avoid head loss Place on a stable level and solid surface e g concrete floor Secure the filter to the ground usi...

Страница 7: ...air release onto the large threaded orifice of the T connector Tip installing the bleed screw The bleed screw already contains its own seal do not use Teflon tape to seal Screw the pressure gauge ont...

Страница 8: ...ion of the filter Pass a nut around the bent pipe then position the assembly without bonding in this step see image Gently tighten the nut and firmly tighten the nut to obtain perfect alignment betwee...

Страница 9: ...nifold and its strainers Level the filter media as it is poured in Then pour in the fine grain filter media up to the required level See the label on the filter for the amounts of filter media to use...

Страница 10: ...to the filter media and returned to the pool Pool suction open Pool discharge open Filter inlet or outlet open Discharge to the drainage system closed Position Backwash The filter media is backflushed...

Страница 11: ...ilter and sent directly to the pool Pool suction open Pool discharge open Filter inlet or outlet closed Discharge to the drainage system closed Position Closed Water no longer circulates in the multiw...

Страница 12: ...ion backwash Start the pump When the filter level is at maximum water comes out of the air bleed screw close the cover air bleed screw Check that there are no leaks on the hydraulic circuit When start...

Страница 13: ...in When the water appears clear through the transparent window on the side of the multiway valve switch off the filter pump Set the valve to the rinse position and switch the filtration system back on...

Страница 14: ...level see 2 2 3 Filling the filter Replace the damaged manifold and or manifold strainers The pressure gauge needle shakes violently Air leak in the circuit Suction valves half closed Check the connec...

Страница 15: ......

Страница 16: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...

Отзывы: