 Jandy® Legacy™ Model LRZM Pool/Spa Heater by Zodiac®   

|

   Installation and Operation Manual

are available from your Jandy dealer or by 

contacting the Technical Support Department 

at (800) 822-7933. See Section 11, “Parts List”, 

of this manual for the correct kit number for the 

manifold assembly needed for your altitude. 

Table 1 defines the altitude designations as 

described by the “Standard for Gas Fired Pool 

Heaters”, ANSI Z21.56 in the United States 

and "Gas Fired Appliances For Use At High 

Altitudes", CAN 1-2.17 in Canada.

table 1.   altitude designations For the Legacy Heater

NATURAL GAS

ALTITUDE  

DESIGNATION

UNITED 

STATES

CANADA

LOW ALTITUDE

0-3000 FT

0-2000 FT 

(0-610 m)

MID ALTITUDE

3001-6000 FT

2001-4500 FT

(611-1370 M)

HIGH ALTITUDE

6001-10,000 FT

NOT  

APPLICABLE

LP

LOW ALTITUDE

0-5000 FT

0-4500 FT 

(0-1370 M)

HIGH ALTITUDE

5001-10,000 FT

NOT  

APPLICABLE

1.7.2  dimensions

See Figure 1 for a diagram showing the heater's 

exterior dimensions and dimensions to critical connec-

tions on the heater.

Section 2.  installation instructions

2.1 

introduction

 WaRNiNG

Improper installation or maintenance can cause 

nausea or asphyxiation from carbon monoxide in 

flue gases which could result in severe injury, or 

death. For indoor installations, as an additional 

measure of safety, Zodiac Pool Systems, Inc. 

strongly recommends installation of suitable Carbon 

Monoxide detectors in the vicinity of this appliance 

and in any adjacent occupied spaces.  

 aveRtiSSeMeNt

Une installation ou un entretien inadéquat peut 

causer la nausée ou l’asphyxie en raison du 

monoxyde de carbone présent dans les gaz de 

combustion et même entraîner des blessures 

graves ou la mort. Pour les installations intéri-

eures, comme mesure de sécurité additionnelle, 

Zodiac Pool Systems, Inc. recommande fortement 

l’installation de détecteurs de monoxyde de carbone 

près de cet appareil ainsi que dans les espaces 

adjacents occupés.

Install the Legacy heaters, vent caps and draft-

hoods in accordance with the procedures in this 

manual, local codes and ordinances, and in accordance 

with the latest edition of the appropriate national code. 

See Section 1.4 "Codes and Standards".

All gas-fired products require correct installation 

to assure safe operation. The requirements for pool 

heaters include the following:

1.  Field assembly (if required)

2.  Appropriate site location (clearances) and floor-

ing

3.  Sufficient combustion and ventilation air

4.  Properly sized gas meter and piping

5.  Proper electrical wiring (if required)

6.  Adequate water flow

This manual provides the information needed to 

meet these requirements. Review all application and 

installation procedures completely before continuing 

the installation.

2.2 

Field assembly 

The Legacy heater is shipped from the factory 

with the top assembly in the low-profile configuration 

for outdoor installation. The Legacy heater is design 

certified for indoor installation (U.S. only) when 

equipped with a draft hood, which must be installed 

without modification. 

The Legacy heater is also certified for installa-

tion in an outdoor shelter in Canada when equipped 

with a draft hood. An outdoor shelter is an enclosure 

not normally occupied which does not communicate 

directly with occupied areas. 

Check the rating plate on the heater or the Parts 

List (Section 11) of this manual for the correct Jandy 

draft hood or vent cap part number. See instructions 

supplied with the draft hood or vent cap for installation 

and attachment. When the draft hood is used, locate 

the heater so as to be in the same atmospheric pressure 

zone as the combustion air inlet to the heater.

2.3 

Location Requirements

2.3.1  introduction

 cautioN

When pool equipment is located below the pool sur-

face, a leak from any component can cause large 

scale water loss or flooding. Zodiac Pool Systems, 

Inc., cannot be responsible for such water loss or 

flooding or resulting damage.

 atteNtioN

Lorsque l’équipement d’une piscine est situé sous 

la surface de l’eau, une fuite provenant de n’importe 

quel élément peut causer une perte d’eau importante 

ou une inondation. Zodiac Pool Systems, Inc.

 

n’est 

pas responsable des pertes d’eau, des inondations 

ou des avaries causées par une installation ou un 

entretien inadéquat.

Содержание Jandy Legacy LRZ Millivolt

Страница 1: ...er installation and or operation can create carbon monoxide gas and flue gases which can cause serious injury property damage or death For indoor installations as an additional measure of safety Zodia...

Страница 2: ......

Страница 3: ...17 5 4 Reversible Water Connections 17 5 5 Connections at Heater 19 5 6 Pressure Relief Valve 19 5 7 Auxiliary Components Chlorinators Ozone Generators and Sanitizing Chemicals 20 Section 6 Electrica...

Страница 4: ...LRZM Pool Spa Heater by Zodiac Installation and Operation Manual Section 11 Replacement Parts 38 11 1 Ordering Information 38 11 2 Parts List 39 11 3 General Exploded View 41 11 4 Detailed Exploded Vi...

Страница 5: ...erved when using the spa AVERTISSEMENT Les R glements suivants pour Cuves Thermales tel que recommand s par la Commission U S de S curit des Produits pour les Consommateurs devraient tre respect s lor...

Страница 6: ...oad on filter systems 1 3 Warranty The Legacy heater is sold with a limited factory warranty Details are specified on the back cover of this manual Make all warranty claims to a Jandy dealer or direct...

Страница 7: ...CPVC pipe nipples to PVC pool plumbing 3 A noncombustible platform for installation on combustible surfaces see Section 2 3 3 Noncombustible bases are available from your Jandy distributor 4 A factor...

Страница 8: ...is manual local codes and ordinances and in accordance with the latest edition of the appropriate national code See Section 1 4 Codes and Standards All gas fired products require correct installation...

Страница 9: ...on all sides for maintenance and inspection There must also be minimum distances maintained from combustible surfaces See Table 2 At least 18 inches 457mm access must be avail able in front of the hea...

Страница 10: ...y a noncombustible panel 2 3 4 Outdoor Installation Legacy heaters can be installed in the low profile top configuration as received from the factory or with an optional high wind vent cap Locate the...

Страница 11: ...e downdraft conditions exist locate the heater at least three 3 feet 0 91 m from vertical surfaces e g nearby buildings and walls The addition of a vent cap may be necessary In Florida it is required...

Страница 12: ...B149 1 For combustion air supply openings however the requirements of Table 3 MUST be followed for safe and proper operation The minimum combustion air openings allowed in CAN CSA B149 1 are NOT suffi...

Страница 13: ...vent pipe and 90 elbows reductions and restrictions Horizontal runs must have at least a 1 4 inch rise per foot 20mm per meter in the direction of flow These requirements are summarized in Table 3 Not...

Страница 14: ...lled to replace an existing pool heater it is recommended that a new appropriate venting system be installed with the new heater However if an existing venting system must be used be sure to carefully...

Страница 15: ...with water after testing ATTENTION Certaines solutions d essai d tanch it y compris l eau et le savon peuvent causer de la corrosion ou de la fissuration Rincez les tuyaux l eau apr s l essai d tanch...

Страница 16: ...f provision for proper ventilation is not made Installation of pool heaters in enclosed areas such as pits is not recom mended Consult the National Fuel Gas Code NFPA 54 ANSI Z223 1 latest edition the...

Страница 17: ...nd adjust the flow using the bypass valve until the proper temperature rise is obtained 5 4 Reversible Water Connections NOTE Reversing the header requires a longer syphon tube order part number R0483...

Страница 18: ...the I O header side cover plates top and bottom See Figure 10 4 Remove the return header side cover plates top and bottom See Figure 10 5 Tag and disconnect the white wire on the pressure switch PS a...

Страница 19: ...aded connection on the header See Figure 12 5 6 Pressure Relief Valve A pressure relief valve PRV is recommended in all installations and is mandatory in any installation in which the water flow can b...

Страница 20: ...g may crack the header atteNtioN Afin d emp cher des d g ts mat riels ne serrez pas trop Le serrage excessif peut provoquer des fissures dans la t te DO NOT TIGHTEN WITH A WRENCH Overtightening may cr...

Страница 21: ...s all electrical equipment in the system and on the equip ment pad Bonding lugs must be connected with a solid copper wire not smaller than 8 AWG 6 AWG in Canada Failure to do so will void warranty Ad...

Страница 22: ...fin de course max 130 Pressure Switch Manostat Pilot Gen G n rateur de veilleuse Pilot Veilleuse Piezo Sparker tinceleur pi zo lectrique Fusible Link Maillon Fusible Fireman Switch Connection Montage...

Страница 23: ...is operation before starting the heater Start the heater in accor dance with the Operating Instructions section of this manual with particular attention to the lighting and shutdown instructions and t...

Страница 24: ...t to your preferences follow the instructions outlined on the following page as shown in Figure 18 Read and follow all safety instructions first A more detailed set of instructions of the opera tion o...

Страница 25: ...s tapes 3 et 4 5 Faire tourner le bouton du robinet gaz vers la gauche jusqu la position ON 6 Apr s avoir remis en place le panneau d acc s r gler le thermostat sur la valeur voulue et mettre l interr...

Страница 26: ...to close at too low of a flow can damage the appliance Adjust the switch to turn the heater off not on ATTENTION Le manocontact de pression d eau doit tre r gl de fa on ce que l appareil cesse de fonc...

Страница 27: ...With the plug removed install the special thread adapter and Pete s Plug fitting and insert a pocket thermometer A temperature rise measurement kit is available through your Jandy distributor See Sect...

Страница 28: ...of the water Be sure to keep your chemical levels within the values indicated in Table 7 Zodiac Pool Systems Inc does not warrant heat exchangers damaged by corrosive chemical levels or excess dissol...

Страница 29: ...especially at spring start up are impor tant to keep your heater running safely and efficiently through the years Improper maintenance can result in conditions where nausea or asphyxiation from carbon...

Страница 30: ...ez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute com mande qui ont t plo...

Страница 31: ...che tenez votre t te et votre visage loin du br leur pour viter tout risque de blessure NOTE Keep this manual in a safe place for future reference by you and your professional technician when inspecti...

Страница 32: ...old gas pressure C Heater size inadequate D Low temperature rise A Gas meter too small Gas line from meter to heater too small B Gas pressure on heater manifold should be adjusted to 4 0 W C natural g...

Страница 33: ...ts in the pool system including pump filters and strainers water valves gas supply and time clocks have an effect on heater operation Confirm that the Legacy heater control switch is set to ON and tha...

Страница 34: ...l temperature in the vent system It is mounted to the flue collector assem bly Excessive temperatures will cause the switch to open Excessive temperatures can be caused by inadequate water flow or a d...

Страница 35: ...n rateur de veilleuse Pilot Veilleuse Piezo Sparker tinceleur pi zo lectrique Fusible Link Maillon Fusible Fireman Switch Connection Montage contacteur pompier 150 High Limit Switch Contacteur de fin...

Страница 36: ...point 1 Touch the black lead of the meter to the terminal of the fusible link where the white wire from the gas valve is connected test point 3 If no voltage is detected at test point 3 the wire betw...

Страница 37: ...e meter to the other terminal of the 130 F 55 C limit switch test point 10 Low or no voltage here means that the limit is open and must be replaced If voltage is detected at test point 10 move the bla...

Страница 38: ...he inlet of the filter system Find the temperature in the chart that is closest to your temperature reading of the pool water Compare your ohmmeter reading to the resistance number in the chart Rememb...

Страница 39: ...gh Limit Switch Assembly All R0457401 39 High Limit Set 130 F 150 F All R0457200 40 High Limit Switch 130 F All R0457300 41 High Limit Switch 150 F All R0023000 Key No Description Model No Order Part...

Страница 40: ...483401 05 98 Heat Deflector Guard Rear 125 400 R0483501 05 99 Controller Mounting Panel 125 400 R0483901 05 100 Weather Stripping All R0491000 101 Grommet 7 8 All R0492800 Optional Components 102 Nonc...

Страница 41: ...tion and Operation Manual Jandy Legacy Model LRZM Pool Spa Heater by Zodiac 11 3 General Exploded View 49 50 51 46 47 45 48 88 94 93 92 56 35 97 83 90 91 101 89 98 96 16 83 11 99 84 85 86 55 58 42 43...

Страница 42: ...dy Legacy Model LRZM Pool Spa Heater by Zodiac Installation and Operation Manual 11 4 Detailed Exploded View 59 63 41 40 62 61 25 33 60 27 79 80 77 59 18 17 13 15 44 9 22 28 31 29 23 24 38 8 3 4 6 1 2...

Страница 43: ...Page 43 ENGLISH Installation and Operation Manual Jandy Legacy Model LRZM Pool Spa Heater by Zodiac 73 74 70 71 76 38 41 40 25 69 68 76 77 79 80 77 67 72 35 75 67 66 65 64 82 55...

Страница 44: ...al S A S U used under license All trademarks referenced herein are the property of their respective owners 2012 Zodiac Pool Systems Inc H0299600 Rev G 1202 Zodiac Pool Systems Inc 2620 Commerce Way Vi...

Отзывы: