Page 9
ENGLISH
Installation and Operation Manual
|
Jandy® Legacy™ Model LRZM Pool/Spa Heater by Zodiac®
The Legacy heater may be installed indoors or
outdoors as outlined in later sections. Location of the
heater below
or above
the pool water level affects
operation of its water pressure switch. See sections on
water piping and heater start-up for more information
about this.
Avoid placing the heater in locations where it
can cause damage by water or condensate leakage.
If this is not possible, provide a suitable drain pan to
catch and divert any leakage. The pan must not restrict
the air flow around the heater.
All criteria given in the following sections
reflect minimum clearances as stated in the national
standards. However, each installation must also be
evaluated, taking into account the prevailing local
conditions such as wind speed and direction, proxim-
ity and height of walls that may block ventilation, and
proximity to public access areas.
2.3.2 clearances
The heater must be placed to provide clearances
on all sides for maintenance and inspection. There
must also be minimum distances maintained from
combustible surfaces. See Table 2.
At least 18 inches (457mm) access must be avail-
able in front of the heater for burner removal.
If the heater is to be installed in a garage, or
similar structure, all burners and burner ignition devic-
es must have a minimum 18 inches (457mm) clearance
above the floor.
This heater must be installed at least five (5)
feet (1.52m) from the inside wall of a pool unless the
heater is separated from the pool by a solid fence, wall
or other permanent solid barrier.
Ce chauffe-piscine doit être installé au moins
5 pieds (1.52m) de la paroi interne de la piscine à
moins d'être isolé de la piscine par une clôture, un
mur ou autre barrière permanente.
Figure 1. General configuration
A
7 5/8"
39 3/8"
2 3/4"
10 3/8"
16"
5"
8"
28 1/2"
13 1/8"
H
41"
Model
Heater Width
Dim "A"
Venting Dimensions
Firing Rate
Vent Diameter
U.S. Outdoor
Dimension "H"
U.S. Indoor or
CAN Outdoor Shelter
Dimension "H"
in.
cm
in.
cm
in.
cm
in.
cm
BTU/HR
kcal/HR
125
15⅛
38
6
15
18
46
24⅛
61
125,000
32
175
18⅛
40
6
15
18
46
24⅛
61
175,000
44
250
22¾
58
7
18
18¼
47
25¼
64
250,000
63
325
26⅞
68
8
20
18⅞
48
26½
67
325,000
82
400
32⅜
82
9
23
21½
55
27½
70
399,000
101