Page 18
ENGLISH
Zodiac
®
Jandy
®
Heat Pumps Model EE-Ti
|
Installation and Operation Manual
4. Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(See Figure 12b).
5. Restore power to the heat pump and the pool/spa
control system.
4.5.2.3 Configure the Control panel
1. Make sure the control is in the
oFF
mode.
2. To enter the Service Setup mode, press and hold
the
Menu
,
pool
, and
spa
buttons for 5
seconds.
note
The display will revert back to
oFF
after one
minute since the last key press.
3. Press the
up
or
down
button to display
reMote
. The
seleCt reMote oFF
(default remote) appears, use the
up
or
down
button to scroll through the Remote options. When
you reach
reMote tstat
, press the
Menu
button to select the remote. Press
pool
or
spa
to exit the Service Setup mode.
4. Press
spa
. For heating, adjust the setpoint to the
maximum setting. For chilling, adjust the setpoint
to the minimum setting.
4.5.3 Four-Wire Connection to aqualink
®
rs 485 Communication
1. Confirm the EE-Ti heat pump and AquaLink RS
software revisions are compatible (see Figure 14).
note
Only a revision "N", or higher, program chip in
the RS system will support the EE-Ti heat pump
interface.
2. Turn off the power to both the heat pump and
the RS control and open the RS Power Center
enclosure and remove the front dead panel.
3. Remove the two (2) screws holding the bezel in
place and turn the bezel over to view the circuit
board on the back.
4. Locate the programmed chip on the Power Center
Board. In the center of the chip is the revision
letter. If the revision letter is "
n
" or higher go to
step 5. If the revision level is "
MMM
" or lower,
replace the board or connect as shown in Section
4.5.2.
5. Use 22 gauge 4-conductor wire (Zodiac Part No.
4278) to run between the heat pump and the RS
control, and match the wire color order.
6. The wires coming from the EE-Ti heat pump can
be “doubled up” on the red terminal bar with the
four (4) wires coming from the indoor controller.
note
If you need to install more than two (2) wires in
each terminal, order a Zodiac Multiplex PCB Kit,
1
2
3
4
RED
BLK
YEL
GRN
®
JANDY AquaLink RS
FILTER PUMP OFF
AIR 79°
06/26/04 MON
6:00 PM
EQUIPMENT ON/OFF
ONETOUCH ON/OFF
MENU / HELP
OR
4-Conductor
Wire
EE-Ti Heat Pump Power Interface
OPTIONAL
4 3 2 1
RED
BLK
YEL
GRN
RS Power
Center
S1
S2
RESET
SERVICE
TIME OUT
FIL
TE
R P
UM
P
AU
X 1
AU
X 2
AU
X 3
AUX
4
AU
X 5
AUX
6
AUX
7
RS6 & RS8 ONLY
RS8 ONLY
HEATER
SOLAR
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL
AUTO
6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
4 3 2 1 4 3 2 1
OR
Thu January, 2009 3:03 PM
AquaLink Touch
Home
Menu OneTouch
Help
Back
Status
Photos Power
FILTER
PUMP
SPA
POOL
HEAT
Pool Temp
86º
Air Temp
78º
SPA
HEAT
AUX1
AUX2
AUX3
Other
Devices
On/Off
Figure 14. ee-ti Heat pump Connection to power
Center
which includes the Multiplex Board (Zodiac Part
No. 6584). Never put more than two (2) wires
into each of the pins of the terminal bar.
7. Check all wiring, then apply power to both the
heat pump and the RS control system. Operation
can be verified in either Service or Auto mode. See
the RS Control System manual for instructions
about operation.
When the EE-Ti heat pump is first powered and
there is an RS control connected to the heat pump, the
display on the heat pump will show
"JandY reMote
online pusH Menu to disaBle"
. When the
EE-Ti heat pump is online with the RS control, all
functionality of the control on the heat pump is disabled.
The heat pump functions can be controlled only at the
RS unit.
To temporarily use the heat pump controls, press
the
Menu
button. The message
"JandY reMote
online pusH Menu to disaBle"
will disappear
from the heat pump display. All functionality has now
been returned to the control on the heat pump. In this
mode the RS unit is no longer controlling the heat
pump.
To return the functionality to the RS unit, cycle
(turn off and then turn on) the power to the heat pump,
or press the
Menu
button for 5 seconds to enter the
User Setup Mode and then enable the Zodiac Remote.