background image

正信光电科技股份有限公司

ZNSHINE PV-TECH CO.,LTD

Mounting Manual

INSTALLATION INSTRUCTION FOR DOUBLE GLASS WITH FRAME SOLAR MODULE

Double glass with frame solar modules are made of crystalline solar cells in series with high efficiency, high

transmission and low iron toughened glasses , anti-aging EVA and high flame-resistant back sheet to laminate,
and anodized aluminum alloy frame. Products have high efficiency, lifespan easy installation, high wind
resistance etc.

Products are made according to international standard IEC61215-2016; IEC61730-2016 and have passed

authority test center’s examination. Our products can be used in home roof solar systems, PV stations,
communication stations, petrol, ocean, meteorological, traffic and solar building etc.

Information for installers
Installers must read and understand this manual before installation.
Please ensure that installation, operation and maintenance of your photovoltaic system is only carried

out by qualified persons able to carry out the technical procedures described in this manual, i.e. system planers,
installers and maintenance personnel, and is carried out in accordance with all safety precautions in this manual
and any and all applicable local codes. If you do not possess these qualifications, you may not carry out the work
described herein except for cleaning.

This manual and the instructions set forth herein are part of the product and should therefore be kept for

the entire useful life of the solar installation.

Information for operators
Keep these instructions safe for the entire useful life of the solar installation.
Please contact your plant supplier for information concerning the formal requirements for solar systems.

Please be sure to learn about directives and permit requirements from the responsible local authorities and
energy providers prior to installation of the solar plant.

We recommend that you insure your solar system against natural hazards (e.g. against lightning strikes).

Содержание Mono-Si Series

Страница 1: ...ntenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personne...

Страница 2: ...se rating A 15A Nominal Mass kg 26 5kg 25 5kg 18kg 21 5kg 26 5kg 25 5kg Package Size mm 1978x992x25 27 30 35 2000x1002x25 27 30 35 1658x992x25 27 30 35 1678x1002x25 27 30 35 1978x992x25 27 30 35 2000x...

Страница 3: ...r fountain Antisepsis keep away from salt erode and sulfuration places Do not wear rings jewelry watches or other metallic items while working with photovoltaic modules 3 Mounting and notes The module...

Страница 4: ...be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will be satisfactory during the rest of the year The module tilt angle is measured between t...

Страница 5: ...t and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influe...

Страница 6: ...dules are strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used must not come into contact with the front glass and m...

Страница 7: ...made of durable corrosion resistant and UV resistant material All mounting hardware bolt flat washer split washer nut should be stainless steel M8 size The minimum recommended length for each clamp is...

Страница 8: ...on Ensure that they are in perfect electrical and mechanical condition Use only cables having one conductor Select the appropriate cable diameter to minimize voltage drop to calculate the minimum cabl...

Страница 9: ...nd the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arcing Mod...

Страница 10: ...d glass 8 as poly panels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8 5 3 4 1 2 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Roa...

Страница 11: ...395 Max Power Voltage Vmp V 39 8 40 40 2 40 4 Max Power Current Imp A 9 55 9 63 9 71 9 78 Open Circuit Voltage Voc V 48 5 48 7 48 9 49 1 Short Circuit Current Isc A 10 04 10 10 10 17 10 25 Module Seri...

Страница 12: ...Series Fuse A 15 Electrical Performance STC Model Type ZXP6 LD72 345 P ZXP6 LD72 350 P ZXP6 LD72 355 P Max Power Pm W 345 350 355 Max Power Voltage Vmp V 38 38 2 38 4 Max Power Current Imp A 9 08 9 17...