flow coding (4digit)

production date (2digit)

Two numbers minus 12 is the actual date

production month (2digit)

Two numbers minus 18 is the actual

Producing year (2digit)

Two numbers minus 15 is the actual year

Department

No.1,2,3,4

stands

for

Znshine

Factory

The very day order time(1-9according to the sequence)

1 as mono panels doped with boron, non-coated glass

2. 2 as poly panels, non-coated glass;

5 as mono panels doped with gallium, non-coated glass;

7 as mono panels doped with boron, coated glass

8 as poly panels, coated glass;

9 as mono panels doped with gallium, coated glass;

第 11.12 位数字码

第 9、10 位数字码

第 6 位数字码

第 7、8 位数字码

第 5 位数字码

第 3 位数字码

4

位数字码

第 1、2 位数字码

PV modules were manufactured by ZNshine ZNSHINE

PV-TECH Co., Ltd.

( No.1 , South Zhenxing Road ,

Industrial Zone , Zhixi Town , Jintan District ,

Changzhou City ,Jiangsu Province,China)

Not free from PID/ Free from PID (one number):

0 represents for 3BB modules which are not free from

PID;

1 represents for 3BB modules which are free from PID;

2 represents for 4BB modules which are not free from

PID;

3 represents for 4BB modules which are free from PID;

4 represents for 5BB modules which are not free from

PID;

5 represents for 5BB modules which are free from PID;

6 represents for 12BB modules which are not free from

Содержание Mono-Si Series

Страница 1: ...ntenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personne...

Страница 2: ...se rating A 15A Nominal Mass kg 26 5kg 25 5kg 18kg 21 5kg 26 5kg 25 5kg Package Size mm 1978x992x25 27 30 35 2000x1002x25 27 30 35 1658x992x25 27 30 35 1678x1002x25 27 30 35 1978x992x25 27 30 35 2000x...

Страница 3: ...r fountain Antisepsis keep away from salt erode and sulfuration places Do not wear rings jewelry watches or other metallic items while working with photovoltaic modules 3 Mounting and notes The module...

Страница 4: ...be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will be satisfactory during the rest of the year The module tilt angle is measured between t...

Страница 5: ...t and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influe...

Страница 6: ...dules are strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used must not come into contact with the front glass and m...

Страница 7: ...made of durable corrosion resistant and UV resistant material All mounting hardware bolt flat washer split washer nut should be stainless steel M8 size The minimum recommended length for each clamp is...

Страница 8: ...on Ensure that they are in perfect electrical and mechanical condition Use only cables having one conductor Select the appropriate cable diameter to minimize voltage drop to calculate the minimum cabl...

Страница 9: ...nd the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arcing Mod...

Страница 10: ...d glass 8 as poly panels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8 5 3 4 1 2 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Roa...

Страница 11: ...395 Max Power Voltage Vmp V 39 8 40 40 2 40 4 Max Power Current Imp A 9 55 9 63 9 71 9 78 Open Circuit Voltage Voc V 48 5 48 7 48 9 49 1 Short Circuit Current Isc A 10 04 10 10 10 17 10 25 Module Seri...

Страница 12: ...Series Fuse A 15 Electrical Performance STC Model Type ZXP6 LD72 345 P ZXP6 LD72 350 P ZXP6 LD72 355 P Max Power Pm W 345 350 355 Max Power Voltage Vmp V 38 38 2 38 4 Max Power Current Imp A 9 08 9 17...

Отзывы: