Equipment Communication 

The background PC software is able to communicate with the system according to three protocols (TCP/IP, RS485 
and WIFI) for data exchange and remote management. 

4.1

 

Access Control Networking Wires and Wiring 

1)

 

RS485 communication wires are made of internationally accepted shielded twisted pairs (RVVSP), which prove 
effective to prevent and shield interference. 

2)

 

The power supply is 12V DC converted from 220V or PoE.   

3)

 

The Wiegand readers use 6-core communication shielded wires (RVVSP 6×0.5mm) (usually there are 6-core, 
8-core, and 10-core types available for users to select according to the ports) to reduce interference during 
transmission. 

4)

 

As an electronic lock has a big current, it generates strong interference signal during an action. To reduce the 
effect of an electronic lock during an action on other elements, 4-core wires (RVVP 4×0.75mm

2

, two for a 

power supply and two for a door sensor) are recommended. 

5)

 

“EXT RS485” interface use 4-core communication shielded wires (RVVSP 4*0.5mm). 

6)

 

Other control cables (like exit switches) are all made of 2-core wires (RVVSP 2×0.5mm

2

). 

7)

 

Notes for wiring: 

 

Signal wires (like network cables and RS485 wires) can neither run in parallel with nor share one casing 

pipe with large-power electric wires (like  electronic lock wires and power cables). If parallel wiring is 

unavoidable for environmental reasons, the distance must be over 50cm. 

 

Try to avoid use of any conductor with a connector during distribution. When a connector is indispensable, 

it must be crimped or welded. No mechanical force can be applied to the joint or branch of conductors. 

 

In a building, distribution lines must be installed horizontally or vertically. They should be protected in 

casing pipes (like plastic or iron water pipes, to be selected according to the technical requirements of 

indoor distribution). Metal hoses are applicable to ceiling wiring, but must be secure and good-looking. 

 

Shielding measures and shielding connection: If the electromagnetic interference in the wring 

environment is found strong in the survey before construction, it is necessary to consider shielding 

protection for data cables when designing a construction scheme. Overall shielding protection is required 

if there is a large radioactive interference source or wiring has to be parallel with a large-current power 

supply on the construction site. Generally, shielding measures include: keeping a maximum distance from 

any interference source, and using metal wiring troughs or galvanized metal water pipes to ensure reliable 

grounding of the connection between the shielding layers of data cables and the metal troughs or pipes. 

Note that a shielding enclosure can have a shielding effect only when it is grounded reliably. 

 

Ground wire connection method: Reliable large-diameter ground wires in compliance with applicable 

national standards are needed on the wiring site, and should be connected in a tree form to avoid DC loop. 

These ground wires must be kept far away from lightning fields. No lightning conductor can serve as a 

ground wire, and ensure there is no lightning current through any ground wire when there is lightning. 

Metal wiring troughs and pipes must be connected continuously and reliably, and linked to ground wires 

through large-diameter wires. The impedance of this section of wire cannot exceed 2ohm. The shielding 

layer also must be connected reliably, and grounded at one end to guarantee uniform current direction. 

The ground wire of the shielding layer must be connected through a large-diameter (not smaller than 

2.5mm

2

) wire. 

Содержание C5S120

Страница 1: ...USER MANUAL C5S110 120 140 Version 1 1 Date Apr 2018 ...

Страница 2: ...About This Manual This manual introduces C5S110 120 140 access control panel installation connection and user instructions ...

Страница 3: ...cess Control Panel Wires 7 3 3 Control Panel System Installation 8 3 4 Control Panel Connection Terminals 9 3 5 Connection with Door Sensors Exit Switches and Auxiliary Input Devices 12 3 6 Connection with Readers 13 3 7 Relay Output Connection 15 3 8 Access Control Panel System Power Supply Structure 17 4 Equipment Communication 19 4 1 Access Control Networking Wires and Wiring 19 4 2 TCP IP Comm...

Страница 4: ...tempt unauthorized repair of the equipment Disassembly or detachment is likely to cause shock or other risks All repair jobs should be done by qualified repair personnel 7 Damages in need of repair In any of the following cases first disconnect the power supply from the equipment and notify qualified repair personnel for repairs The power cord or connector is damaged There is entry of liquid or an...

Страница 5: ... We will not be responsible for the damages or injuries caused thereby Before installation switch off the external circuit that supplies power to the system including locks Before connecting the equipment to power supply ensure the output voltage is within the specified range Never connect power before completion of installation ...

Страница 6: ... tools may be used to avoid short circuit or communication failure resulting from accidental contact with excessive exposed wires 9 To save access control event records export data periodically from control panels 10 Get prepared countermeasures according to application scenarios for unexpected power failure like selecting power supply with UPS 11 If RS485 reader is connected externally and shares...

Страница 7: ...ol panel Over current protection for the power supply to card readers Instant over voltage protection for all input output ports Instant over voltage protection for communication ports 2 2 Product Technical Parameters Working power supply Rated voltage 12V 20 DC rated current 3A rated current for C5S140 5A Working environment Temperature 10 C 50 C humidity 20 80 Electronic lock relay output The ma...

Страница 8: ...oduction 5 3 WLAN indicator green flashing indicates the system is communicating in wireless WIFI mode 4 DOOR indicator green flashing indicates a door opening signal a door is opened Diagram of C5S140 indicators ...

Страница 9: ...you need to install the control panel separately without the chassis you can use the guide rail to fix the control panel The following figures show how to fix the control panel using the guide rail The following shows the chassis appearance and internal structure Panel Box Appearance Panel Box Inside Get the Panel off the track Remove the set screws Control Panel Temper Switch Power Adapter Guide ...

Страница 10: ...to the equipment The access control wires must be separated according to heavy and light current the control panel wires electronic lock wires and exit button wires must run through their respective casing pipes TCP IP network communication wire or PoE line for PoE only RS485 network communication wire Control Panel Door sensor Electronic lock Exit button Indoor reader Outdoor reader Outdoor Indoo...

Страница 11: ...spite the preceding example of four door one way two way C5S140 also can be connected to two door two way C5S110 can be connected to one door one way two way at most and C5S120 can be connected to two door one way two way The access control management system consists of two parts management workstation PC and control panel ...

Страница 12: ...h power wires A management workstation is actually a PC connected to the network By running the access control management software installed in the PC access control management personnel can remotely perform various management functions like adding deleting a user viewing event records opening closing doors and monitoring status of each door in real time 3 4 Control Panel Connection Terminals C5S1...

Страница 13: ... DIP Switch PC RS485 Auxiliary Output Ethernet PoE Interface USB Slot Reset Disassembly Mains Battery Abnormality Alarm Power Input Auxiliary Input 1 Door State Indicator 2 Door EXT RS485 Wiegand Reader 1 Wiegand Reader 2 Antenna Connector Wiegand Reader 3 Wiegand Reader 4 ...

Страница 14: ...us indicator 4 PC RS485 indicates the RS485 cable is connected to the PC through this port The EXT RS485 port can be connected externally to RS485 reader 5 All the terminals mentioned above are set through relevant access control software Please see the respective software manual for details Rotary DIP Switch PC RS485 Auxiliary Output Ethernet PoE Interface USB Slot Reset Disassembly Mains Battery...

Страница 15: ...oor With a door sensor switch an access control panel can detect illegal opening of a door and will trigger an output of alarm Moreover if a door is not closed within a specified period of time after it is opened the door control panel will also prompt an alarm It is recommended to select two core wires with a gauge over 0 22 mm2 A door sensor may be omitted if it is unnecessary to monitor online ...

Страница 16: ...control panel 3 Auxiliaryinput C5S series control panel provides one auxiliary input interface which are connected to infrared body detectors smoke detectors gas detectors window magnetic alarms wireless exit switches etc Auxiliary inputs are set through relevant access control software Please see the respective software manual for details Connections between C5S140 and Door Sensors Exit Switches ...

Страница 17: ... RS485 interface can supply maximum 750 mA 12V current So the entire current consumption should be less than this max value when the readers share power with the panel In calculation please use max current of the reader and start current is usually more than twice of the normal work current please consider of this situation For example use the KR502M RS card reader the standby current is less than...

Страница 18: ...sed as a control lock by default and the other used as an auxiliary output C5S120 has three relays two used as control locks by default and the other one used as auxiliary outputs C5S140 has five relays four used as control locks by default and the other one used as auxiliary outputs The relays for auxiliary outputs may be connected to monitors alarms door bells etc Auxiliary outputs are set throu...

Страница 19: ...ess control system against the self induced electromotive force generated by an electronic lock at the instant of switching off on it is necessary to connect a diode in parallel please use the FR107 delivered with the system with the electronic lock to release the self induced electromotive force during onsite connection for application of the access control system The following uses the example o...

Страница 20: ...Installation and Connection 17 3 8 Access Control Panel System Power Supply Structure Access Control Panel System Power Supply PoE System ...

Страница 21: ...oE the TCP IP network interface of the access control panel can serve as a PoE interface and a PC communication interface The PoE switch must conform to IEEE802 3at standards To prevent power failure of a control panel from making the whole system unable to work normally the access control management system is usually required to have one UPS at least and access control locks are powered externall...

Страница 22: ...ally or vertically They should be protected in casing pipes like plastic or iron water pipes to be selected according to the technical requirements of indoor distribution Metal hoses are applicable to ceiling wiring but must be secure and good looking Shielding measures and shielding connection If the electromagnetic interference in the wring environment is found strong in the survey before constr...

Страница 23: ...mmunication wires should be connected by means of bus cascade connection instead of in a star form to achieve a better shielding effect by reducing signal reflection during communications 3 Considering stability of communication it is recommended the length of RS485 bus is less than 600m 4 Up to 16 device numbers can be set because the rotary DIP switch on the control panel has 16 bits Therefore a...

Страница 24: ...access the ZKPanelWeb Note 1 Must configure IP address of the controller and Server PC in the same network segment 2 When the controller s IP address is unknown you can obtain the IP through searching device in the software 3 Click TCP IP Settings to modify the IP address and gateway address Extended Network Card Setting is set when the controller is connected to TCP IP reader For detailed setting...

Страница 25: ...connection status shows connected as shown in Figure 2 and the device s WLAN indicator turns green figure 1 figure 2 Note The PC server must be on the same network segment as the router wireless network 6 Switch network connection in the software For ZKAccess3 5 software Select the added C5S control panel on the Device page and click More Set up WiFi as figure 3 set the WIFI parameters of the cont...

Страница 26: ...ates device number 1 and so on Switch F indicates device number 15 You can rotate the 0 F bits of the rotary DIP switch to corresponding positions to set device numbers and then restart the control panel to make the setting take effect Address numbers cannot be repetitive 4 6 USB Upgrade The USB slot is primarily used for control panel upgrade the following describes how to use it 1 Create a Udisk...

Отзывы: