Installation and Connection 9
The management workstation and control panel communicate through TCP/IP, RS485, and wireless network (WIFI).
On a single RS485 bus, each management workstation can be connected to a maximum of 16 C5S control panels
(with a maximum of 16 bits of DIP switch, a maximum of 16 device numbers can be set). The communication
wires should be kept away from high-voltage wires as far as possible, and should be neither routed in parallel with
nor bundled with power wires.
A management workstation is actually a PC connected to the network. By running the access control
management software installed in the PC, access control management personnel can remotely perform various
management functions, like adding/deleting a user, viewing event records, opening/closing doors, and
monitoring status of each door in real time.
3.4
Control Panel Connection Terminals
C5S110 terminal connection diagram
Antenna
Connector
EXT RS485
Wiegand Reader 2
Rotary DIP Switch
Eth
ern
et/
Po
E I
nte
rfa
ce
US
B
Slot
Res
et
D
isa
sse
m
bly/
M
ain
s/B
atte
ry
Ab
no
rm
ality
Ala
rm
Po
we
r
In
put
#1 Door
Auxiliary
Output
Auxiliary
Input
PC RS485
Wiegand Reader 1
State Indicator