Ports on the C5S Series control panel:
No.
Functional Port
C5S110
(One-Door
Two-Way)
C5S120
(Two-Door
Two-Way)
C5S140
(Four-Door One-Way/Two-Door
Two Way)
1
Wiegand reader interface
2
4
4
2
Exit button
1
2
4
3
Control lock relay
1
2
4
4
Door sensor
1
2
4
5
Auxiliary Input
1
1
1
6
Auxiliary Output
1
1
1
7
RS485 reader
2
4
8
8
RS485 & PC communication
√
√
√
9
RS485 extension
communication
√
√
√
10
TCP/IP
√
√
√
11
Wireless communication
(WIFI)
√
√
√
3.5
Connection with Door Sensors, Exit Switches, and Auxiliary Input Devices
1)
Door sensor
A door sensor is used to sense the open/closed status of a door. With a door sensor switch, an access control
panel can detect illegal opening of a door, and will trigger an output of alarm. Moreover, if a door is not closed
within a specified period of time after it is opened, the door control panel will also prompt an alarm. It is
recommended to select two-core wires with a gauge over 0.22 mm
2
. A door sensor may be omitted if it is unnecessary to
monitor online the open/closed status of a door, give out an alarm when the door is not closed for a long time or there is
illegal access, and use the interlock function.
2)
Exit switch
An exit switch is a switch installed indoors to open a door. When it is switched on, the door will be opened. An exit
button is fixed at a height of about 1.4m above the ground. Ensure it is located in the right position without slant,