Installation and Connection 13
and its connection is correct and secure. (Cut off the exposed end of any unused wire and wrap it with insulating
tape.) Note to guard against electromagnetic interference (such as light switches and computers). It is
recommended to use two-core wires with a gauge over 0.3mm
2
as the connection wire between an exit switch and a
control panel.
3)
Auxiliary input
C5S series control panel provides one auxiliary input interface; which are connected to infrared body detectors,
smoke detectors, gas detectors, window magnetic alarms, wireless exit switches, etc. Auxiliary inputs are set
through relevant access control software. Please see the respective software manual for details.
Connections between C5S140 and Door Sensors, Exit Switches, and Auxiliary Input Devices
3.6
Connection with Readers
The control panel supports RS485 reader and Wiegand reader (Note: The control panel does not support