802005UK - Residential (Boiling),chilled and sparkling installation instructions - Aug 2015 - v2.01
Page 29 of 40
Installation instructions
5.3 Boiling, chilled and sparkling Hydrotap
®
G4
models
(for Arc / Cube, also refer to the tube kit
assembly instructions supplied with the tap head).
Arc / Cube
Elite
Classic
Note
Neither the braided hoses or the tubes supplied with the tap can be lengthened. Take time to consider
hose lengths when determining the mounting positions and cover the chilled and sparkling pipes with the
insulation provided.
Not required for standard BCS HydroTap
®
G4 models.
RED
CLEAR
BLUE
BRAIDED
WHITE
BRAIDED
POWER
CABLE
USB
CHILLED
OUT
MAINS
IN
MIXER
OUT
MIXER
IN
BOILING
OUT
BYPASS
OUT
VENT BYPASS
IN
SPARKLING
OUT
CO2
IN
535mm
280mm
50mm
50mm
Cold isolation valve
(not supplied)
Clearance
envelope
Note
Mains hose length is
750mm.
Electrical power cable length is
1800mm.
Position the Command-Centre
TM
according to the hose and cable
lengths supplied.
Note
All plastic / silicon tubes
must be trimmed to size. They
must have a constant fall to the
Command-Centre
TM
.
(Supplied)