Page 20 of 40
802005UK - Residential (Boiling),chilled and sparkling installation instructions - Aug 2015 - v2.01
Installation instructions
Installing the All-in-One ‘Vented’ tap
(see page 32 for Command-Centre
TM
installation).
1.19 All-in-One ‘Vented’ connections.
• Connect the red and clear silicone tubes & USB
cable to the Command-Centre
TM
as shown.
• Connect the blue and white plastic pipe supplied
to the Y connector in place on the end of the blue
silicone tube, then connect to the Command-
Centre
TM
as shown.
• Working from inside the cupboard, attach the
braided hoses to the tube extensions (ensure the
seals on the end of the hoses are lubricated).
Check the correct position for mixer and ambient
connections by matching the colours on the
braided hoses with the coloured markings on the
extension tubes. (See adjacent diagram).
• Connect the braided hose with the blue marking to
the ‘MIXER IN’ on the Command-Centre
TM
.
• Connect the braided hose with the white marking
to the Restrictaflow.
• Connect the braided hose with the red marking
to the metal tube, with red marking then to the
‘MIXER OUT’ on the Command-Centre
TM
.
• Ensure that all tubes and
hoses are firmly secured.
Braided hose
connection to metal
tube - ‘MIXER
OUT’ on Command-
Centre
TM
.
Braided hose with
blue marking - to
MIXER IN’
on Command-
Centre
TM
Clear silicone
tube - VENT on
Command-Centre
TM
Braided hose with
white marking -
Restrictaflow on
ambient supply
Red silicone tube -
BOILING OUT on
Command-Centre
TM
Blue silicone tube Y
connector
blue plastic pipe to-
STILL OUT
white plastic pipe to-
SPARKLING OUT
on the
Command-Centre
TM
1.18 Base block spider markings and silicone tube positions
(viewed from
underneath).
White marking
Blue marking
USB cable
Blue silicone tube
Red silicone tube
Clear silicone tube
Braided hose with
white marking
Braided hose with
blue marking
Braided hose with
red marking
HydroTap
Mixer
Connections
RED
CLEAR
BRAIDED
POWER
CABLE
USB
MAINS
IN
MIXER
OUT
MIXER
IN
BOILING
OUT
BYPASS
OUT
VENT BYPASS
IN
BLUE
BRAIDED
CLEAR
CHILLED
OUT
SPARKLING
OUT
CO2
IN
Booster
Connections