802411US v1.27 06.21 BC, BC100-75 Install Instructions
Page 7 of 32
Important Safety Instructions
WARNINGS
1. The Zip HydroTap Command Center must be earthed. The resistance of the
earth connection from each exposed metal part must be less than 1 ohm.
2. All Installation and service work must be completed by trained and suitably
qualified Tradespeople. Faulty operation due to unqualified persons working
on this product, or any other Zip product may void warranty coverage.
3. All plumbing and electrical must comply with local, state and federal codes.
4. All Plumbing and Electrical connections must be made in accordance with
local regulations.
5. Ensure the electrical power supply at the installation site is suitable for
your HydroTap. HydroTap models are rated for either 110-120V, 60Hz, OR
230V, 50Hz AC installations.
6. Command Centers must never be located near, or cleaned with water jets.
7. Zip HydroTaps are not to be exposed to the elements of nature
8. Due to the process of continuous improvement, Zip reserves the right to
change details mentioned in this manual, without notice.
9. If this device is not maintained and operated as specified in this document,
there is a risk of exposure to contaminants.
10. When dispensing hot water, the device can create a scald hazard.
!
Positioning
It is important to ensure the Command Center is positioned in an accessible area close to the floor level.
The Command Center must have its base mounted in a horizontal position with all inlets and outlets facing
up. The faucet must be located above the Command Center and positioned so that it dispenses into the sink
bowl with ample clearance for a cup or teapot.