802411US v1.27 06.21 BC, BC100-75 Install Instructions
4.3
-
Boiling Calibration
Commissioning
4.4
-
Booster
Press the calibration button to commence the Boiling
calibration procedure. This will take approximately 5-6
minutes.
NOTE: This product does not have a booster option.
When asked if a booster is installed, make sure NO is
selected.
Safety
sensor
Pull both levers forward
1. With the unit in Normal operating mode and with the safety enabled
2. Turn the power OFF
3. Pull both faucet levers to the forward position
4. Turn ON the power
5. The unit will calibrate the safety switch
6. Return the levers to the neutral position.
7. To check the calibration, dispense Boiling water, in normal light
conditions with the safety enabled.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration.
This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.
4.5
-
Sensor
207
127
4.6
-
Conditioning Procedure
Note:
Zip HydroTap Command Centers are sanitized during manufacturing and required final flushing before
normal use.
1. Dispense 6 liters (1.6 gallons) of boiling water from the boiling outlet of the HydroTap (Equivalent to 2
complete tanks full of water)
2. Dispense 10 liters (2.6 gallons) of chilled water from the chilled outlet of the HydroTap (Equivalent to 4
complete tanks full of water)
3. If water bubbles or foams repeat steps 1 and 2 above
4. Let filled tanks stand for one hour at operating temperature
5. After one hour, repeat steps 1 and 2.
6. Product is ready for use.