background image

802411US v1.27 06.21 BC, BC100-75 Install Instructions 

Page 17 of 32

• 

Turn ON the water and gas and check for any leaks. 

• 

Turn the power ON at the outlet and at the side of the Command Center

• 

If fitted, ensure the Booster is turned OFF (the Booster is commissioned, later, at section 4.5)

• 

Familiarise yourself with the operation of the Faucet, in preparation for use (See User Guide)

• 

Follow the Installation instructions below (and review Section C of the User Guide). 

• 

After commissioning, the system may be customised by selecting further options in Section G - 

Settings, within the User Guide.

4.2

 - 

Filter Flush 

Section 4

Commissioning

4.1

 - 

Select the Language 

Initial Commissioning screen

Language selection screen

 Boiling Chilled 

 

10:30 Wed 04,Jul 2018

 Boiling Chilled 

 

10:30 Wed 04,Jul 2018

 Boiling Chilled 

 

10:30 Wed 04,Jul 2018

A new filter cartridge is provided (but NOT fitted), inside the 

filter door. Unpack the new filter cartridge and write today’s 

date on the label. To install the cartridge, align the key tabs 

and insert upwards into the filter head. Turn the cartridge to the 

right until it locks in place. 
Have a 10 liter (2.6 gallon) bucket or similar container (not 

supplied) at the ready to hold a quantity of water that will be 

ejected while the Filter Flush Mode is in operation. Open the 

filter access door on the front of the HydroTap and the filter 

cartridge will be exposed. Located to the rear RHS of the 

cartridge is a flush line and the flush line stop cock. Place the 

valve end of the flush line into the bucket or container.

Note:

 You will need to Press the [Start] [Stop] buttons to start 

and stop the filter flush.

1

1

2

NOTE: 

For any subsequent filter changes or any operational 

procedures, please refer to the HydroTap user guide, located 

inside the filter housing access door.

OPEN 

CLOSED 

Stop cock operation

1.  Turn the flush line stop cock ON  (See diagram).

2.  Press [Start] and allow at least 10 liters (2.6 gallons) of 

water to flush through the filter.

3.  The product details will be displayed in the screen.

4.  Once the filter flush is finished, Turn the stop cock OFF 

then press [Stop] to end filter flush mode. 

Содержание HydroTap BC100/75

Страница 1: ...US v1 27 06 21 BC BC100 75 Install Instructions Page 1 of 32 BC100 75 and BC Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document English F...

Страница 2: ...he customer s needs For ease of installation it is recommended to fit the faucet before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Insta...

Страница 3: ...ation instruction book STEP 2 Check for adequate ventilation Section 2 Ventilation 2 1 Ventilation for all models 11 2 2 Cabinet air circulation 12 13 STEP 3 Install the Command Center Section 3 Comma...

Страница 4: ...k the appliance rating plate and ensure correct power is available for the appliance G Check the under counter cabinet supporting the appliance is adequate for the total weight of the appliance when f...

Страница 5: ...efrigerant compressor to chill the water and an immersion heating element to boil the water These Command Centers dispense boiling water factory set to 98 C 208 F and chilled water factory set to 6 10...

Страница 6: ...rocedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or condensed droplets...

Страница 7: ...r HydroTap HydroTap models are rated for either 110 120V 60Hz OR 230V 50Hz AC installations 6 Command Centers must never be located near or cleaned with water jets 7 Zip HydroTaps are not to be expose...

Страница 8: ...d water filters 1x Mains water connection hose Vent Kit 1x Inlet vent 1x Outlet vent 9 x Screws 1x Installation Instructions this book and 1x User Guide Accessories Description Font Drip Tray Kit for...

Страница 9: ...efers to the specific finish of the faucet BC Classic XX BC ARC XX BC CUBE XX BC100 75 Classic XX BC100 75 CUBE XX and BC100 75 ARC XX have been tested and certified by WQA against NSF ANSI Standard 3...

Страница 10: ...nside the cabinet within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centers are installed A cold water supply with...

Страница 11: ...m Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps are achieved...

Страница 12: ...r the inlet vent See Item B below and silicone buffers need to be fitted If the airflow is still insufficient to maintain normal operating temperatures then the door outlet vent See item D below will...

Страница 13: ...d cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure wi...

Страница 14: ...ect the plug into the electrical power outlet ensuring both ends are securely engaged to reduce the risk of overheating Section 3 Command Center Installation B Rotate 90 only 1 2 3 4 A Rotate 90 only...

Страница 15: ...y pulling back on the tube If the tube comes out of the fitting repeat the above step 5 To remove the tube press the collet into the fitting and at the same time pull back on the tube 3 3 Hose and tub...

Страница 16: ...HydroTap models Note The tube lengths are matched to the pump performance and therefore CANNOT be lengthened 336mm 13 5 Connector Strainer Min 50mm 2 side clearance Note Mains hose length is 750mm 30...

Страница 17: ...label To install the cartridge align the key tabs and insert upwards into the filter head Turn the cartridge to the right until it locks in place Have a 10 liter 2 6 gallon bucket or similar containe...

Страница 18: ...efore it is recommended that a re calibration be performed at the time of the installation All direct natural sun light must be shaded from the HydroTap during the calibration This can be achieved by...

Страница 19: ...ser sensor Open Internal fault Check ventilation Call Zip service Heater fuse driver fault Internal fault Call Zip Service Heater driver fault No hot water Call Zip Service Compressor driver fault No...

Страница 20: ...nment we ask that you dispose of this product correctly This product should not be treated as domestic waste but should be taken to a dedicated recycling center for electrical and electronic equipment...

Страница 21: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Страница 22: ...n or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Red...

Страница 23: ...an or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Re...

Страница 24: ...imit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Redu...

Страница 25: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requ...

Страница 26: ...the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requir...

Страница 27: ...the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requir...

Страница 28: ...replace the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is in...

Страница 29: ...Zip Servicer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is commit...

Страница 30: ...Page 30 of 32 802411US v1 27 06 21 BC BC100 75 Install Instructions Notes...

Страница 31: ...802411US v1 27 06 21 BC BC100 75 Install Instructions Page 31 of 32 Notes...

Страница 32: ...ndard 42 and NSF ANSI Standard 53 This will deliver the re quired bacteriostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to 1 m cyst and lead as ver...

Отзывы: