Page 22 of 32
802411US v1.27 06.21 BC, BC100-75 Install Instructions
Performance Data Sheet
Performance Data Sheet
Zip Hydrotap BC – ARC XX*
Manufacturer:
Zip Water (Aust) Pty. Ltd
67 Allingham Street, Condell Park NSW 2200
Australia
Distributed in US and Canada by: Culligan International Company
Call Zip’s US distributor Culligan International Company on US Toll Free
1-833-233-2358 for assistance, service, spare parts or enquiries.
Testing Conditions and Results:
Flow Rate: 1 gpm
Capacity: 1,100 gallons
Pressure: 60 psig ± 3
pH: 7.5 ± 0.5
Temperature: 68 ± 5 °F
Operating Conditions
Minimum Working Pressure: 37 psi (2.60 kg/cm
2
)
Minimum Operating Temperature: 41 °F (5 °C)
Maximum Working Pressure: 100 psi (7.03 kg/cm
2
)
Maximum Operating Temperature: 95 °F (35 °C)
Electrical Characteristics: 230V/50 Hz or 110-120V/60Hz (model dependent)
Replacement Cartridge: 1Z-LS (Culligan P/N 01034276)
Operating TDS: 50 ppm – 150 ppm
Substance Reduction
While testing was performed under standard laboratory conditions, actual performance may vary.
This system, used in conjunction with the above-mentioned filter cartridge, has been tested and
certified by WQA according to NSF/ANSI 42 and NSF/ANSI 53 for reduction of the substances listed
below as verified and substantiated by test data.
This system, used in conjunction with the above-mentioned filter cartridge, has been certified by
IAPMO R&T according to NSF/ANSI 42 and NSF/ANSI 53 for reduction of the substances listed below as
verified and substantiated by test data.
The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system as specified in
NSF/ANSI 42 and NSF/ANSI 53.
Substance
Average Influent
Challenge
Concentration
Max. Permissible
Product
Requirements
Reduction
Requirement
Average
Reduction
NSF/ANSI 42 – Aesthetic Effects
Bacteriostatic Effects
Unit passes NSF/ANSI 42 for Bacteriostatic effects.**
Chlorine, Taste and Odor
2.0 mg/L ± 10%
≥
50%
97.4%
Nominal Particulate Reduction,
Class I (
≥
0.5 µm to < 1 µm)
10,000/mL
≥
85%
99.3%
NSF/ANSI 53 – Health Effects
Cyst
Minimum 50,000/L
≥
99.95%
99.99%
Lead, pH 8.5
0.15 mg/L ± 10%
0.005 mg/L
≥
96.67%
98.9%
Lead, pH 6.5
0.15 mg/L ± 10%
0.005 mg/L
≥
96.67%
99.3%
*Available in a range of premium metallic finishes. XX refers to the specific finish of the faucet.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system. The term ‘bacteriostatic’ means that the system limits the passage or growth of bacteria that
may already exist in the incoming water. It does not mean that the water leaving the system is safer to drink than
the water entering the system.
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
See the installation manual for installation, maintenance requirements and warranty.
Performance Indicator:
Filter Light on LED faucet. Full text notification on LCD display.
To maintain product certification and ensure uniform performance, the product is retested on a consistent basis.
____________________________________
____________________________________
Name & Signature: Buyer
Date
Name & Signature: Seller
Date
Cartridges manufactured for Zip by Pentair Everpure, EPA Est. No.
002623-IL-002. Replacement cartridges can be purchased from your
local Culligan dealer, Zip dealer or other Zip approved distributors.