Zip HydroTap BC100/75 Скачать руководство пользователя страница 28

Page 28 of 32 

802411US v1.27 06.21 BC, BC100-75 Install Instructions

Warranty

Limited Warranty- Zip Products

What Does This Warranty Cover?

Culligan International Company, d/b/a Zip Water, (hereinafter “Zip”), warrants to the original purchaser (the “Zip 

Customer”) of the Zip product (the “Zip Product”), so long as the Zip Customer purchased the Zip Product from an 

authorized Zip dealer (“Authorized Zip Dealer”), that this Zip Product, including any of its original accessories, is free of 

defects in material and workmanship, subject to the terms and conditions set forth herein. This Limited Warranty covers 

parts and labor, except as set forth in this Limited Warranty

Where Is This Limited Warranty Valid?

This Limited Warranty is only applicable if the Zip Product was installed in the United States of America (“USA”).

What Is Required to Request Warranty Service?

All three of the following are required before warranty service will be performed:  (1) Verification of the purchase date; 

(2) Verification that the Zip Product was purchased from an Authorized Zip Dealer; and (3) Verification that the Zip 

Product at issue was installed by an authorized Zip service technician or an approved Zip service provider.

When Does the Limited Warranty Expire?
One (1) Year Limited Warranty

 - Any warranty claims for Zip Products must be received by Zip within 15 months 

from the date of purchase or within 12 months from date of installation.  This warranty guarantees that if any part 

should fail within 15 months from date of purchase or within 12 months from the date of installation, except as detailed 

below, Zip or its authorized service provider will repair or replace the Zip Product.  Determination to repair or replace 

will be in Zip’s sole discretion. Repair or replacement services will be at no cost to the Zip Customer, provided that:
a)  the Zip Product is installed and used strictly in accordance with the instructions supplied; and
b)  all service under the One (1) Year Limited Warranty is carried out only by an authorized Zip service technician or 

an approved Zip service provider.
This warranty includes both parts and labor.

Extended Two (2) Year Limited Warranty

 – In addition to the One (1) year Limited Warranty described above, 

the Zip Customer can opt to extend the Zip Product warranty by one (1) year, making the total Limited Warranty period 

two (2) years. In order to extend the warranty to two (2) years, the Zip Customer must register their product with Zip. 

This extended two (2) year Limited Warranty is subject to the same conditions as provided above in clauses a) and b).

How To Register?

Zip Products must be registered online at https://www.us.zipwater.com 

What If Repair Is Impossible?

If Zip determines that the warranted repair of any Zip Product is impossible, the Zip Product shall, at Zip’s discretion, 

either be replaced or refunded. 

What Is Not Covered by This Limited Warranty?
This Limited Warranty does not cover:

•  Damage or defects caused by, or resulting from, repairs, service, conversion or alterations to the Zip Product 

or any of its parts and accessories which have been performed by service centers or repairmen not authorized by 

Zip; damage or defects caused by negligence, improper installation (when not installed by an authorized Zip service 

provider), accident, abuse, misuse, power interruptions, power surges, unsuitable water conditions, floods, natural 

disasters, or force majeure; or improper maintenance of the Zip Product or its parts or accessories.
•  Ordinary wear and tear.

Содержание HydroTap BC100/75

Страница 1: ...US v1 27 06 21 BC BC100 75 Install Instructions Page 1 of 32 BC100 75 and BC Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document English F...

Страница 2: ...he customer s needs For ease of installation it is recommended to fit the faucet before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Insta...

Страница 3: ...ation instruction book STEP 2 Check for adequate ventilation Section 2 Ventilation 2 1 Ventilation for all models 11 2 2 Cabinet air circulation 12 13 STEP 3 Install the Command Center Section 3 Comma...

Страница 4: ...k the appliance rating plate and ensure correct power is available for the appliance G Check the under counter cabinet supporting the appliance is adequate for the total weight of the appliance when f...

Страница 5: ...efrigerant compressor to chill the water and an immersion heating element to boil the water These Command Centers dispense boiling water factory set to 98 C 208 F and chilled water factory set to 6 10...

Страница 6: ...rocedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or condensed droplets...

Страница 7: ...r HydroTap HydroTap models are rated for either 110 120V 60Hz OR 230V 50Hz AC installations 6 Command Centers must never be located near or cleaned with water jets 7 Zip HydroTaps are not to be expose...

Страница 8: ...d water filters 1x Mains water connection hose Vent Kit 1x Inlet vent 1x Outlet vent 9 x Screws 1x Installation Instructions this book and 1x User Guide Accessories Description Font Drip Tray Kit for...

Страница 9: ...efers to the specific finish of the faucet BC Classic XX BC ARC XX BC CUBE XX BC100 75 Classic XX BC100 75 CUBE XX and BC100 75 ARC XX have been tested and certified by WQA against NSF ANSI Standard 3...

Страница 10: ...nside the cabinet within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centers are installed A cold water supply with...

Страница 11: ...m Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps are achieved...

Страница 12: ...r the inlet vent See Item B below and silicone buffers need to be fitted If the airflow is still insufficient to maintain normal operating temperatures then the door outlet vent See item D below will...

Страница 13: ...d cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure wi...

Страница 14: ...ect the plug into the electrical power outlet ensuring both ends are securely engaged to reduce the risk of overheating Section 3 Command Center Installation B Rotate 90 only 1 2 3 4 A Rotate 90 only...

Страница 15: ...y pulling back on the tube If the tube comes out of the fitting repeat the above step 5 To remove the tube press the collet into the fitting and at the same time pull back on the tube 3 3 Hose and tub...

Страница 16: ...HydroTap models Note The tube lengths are matched to the pump performance and therefore CANNOT be lengthened 336mm 13 5 Connector Strainer Min 50mm 2 side clearance Note Mains hose length is 750mm 30...

Страница 17: ...label To install the cartridge align the key tabs and insert upwards into the filter head Turn the cartridge to the right until it locks in place Have a 10 liter 2 6 gallon bucket or similar containe...

Страница 18: ...efore it is recommended that a re calibration be performed at the time of the installation All direct natural sun light must be shaded from the HydroTap during the calibration This can be achieved by...

Страница 19: ...ser sensor Open Internal fault Check ventilation Call Zip service Heater fuse driver fault Internal fault Call Zip Service Heater driver fault No hot water Call Zip Service Compressor driver fault No...

Страница 20: ...nment we ask that you dispose of this product correctly This product should not be treated as domestic waste but should be taken to a dedicated recycling center for electrical and electronic equipment...

Страница 21: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Страница 22: ...n or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Red...

Страница 23: ...an or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Re...

Страница 24: ...imit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Redu...

Страница 25: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requ...

Страница 26: ...the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requir...

Страница 27: ...the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requir...

Страница 28: ...replace the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is in...

Страница 29: ...Zip Servicer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is commit...

Страница 30: ...Page 30 of 32 802411US v1 27 06 21 BC BC100 75 Install Instructions Notes...

Страница 31: ...802411US v1 27 06 21 BC BC100 75 Install Instructions Page 31 of 32 Notes...

Страница 32: ...ndard 42 and NSF ANSI Standard 53 This will deliver the re quired bacteriostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to 1 m cyst and lead as ver...

Отзывы: