Installation instructions & user manual 

806143UK  V1.00 July 2019 - HydroChill HC45

Technical support

  

Tel: 0345 6 005 005  Email: [email protected]  www.zipwater.co.uk

IMPORTANT SAFETY INSTRUCTIONS

Qualifications 

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, 
all installation procedures must be carried out by a suitably qualified tradesperson. The power cable 
and power outlet must be in a safe visible position for connection.

Lifting

Take care when lifting. The Command Centre may exceed safe lifting limits. If you feel this is 
beyond your personal capabilities, please seek assistance with the lift. The weight of the Command 
Centre is marked on the packaging. Do not lift the Command Centre by the front cover or any of its 
connections. Refer to the technical specification, see page 4, for the weight of the product.

Airflow

The Zip HydroChill operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation 
must be provided. The system will operate satisfactorily only if the recommended air gaps are 
provided. See Section 2 'Ventilation', page 9  for correct installation to prevent overheating. 

Sanitising

For safe operation, the HydroChill is designed to be installed, commissioned and used within 48 
hours. 
Should the HydroChill not be required for an extended period of time (48 hours or more), do not fill 
and commission it until ready for first use.
The HydroChill must be sanitised during the commission process, please contact 

 

the Zip Water 

team on 0345 6 005 005 to book your commissioning service.
For water taste and quality reasons any non-use of more than 48 hours, Zip recommend a system 
flush be performed.  
On first use after a period of non-use, run the chilled & ambient water functions for 60 seconds to 
flush the filter and system. 
Not flushing the system may affect water the quality.

WARNINGS AND REGULATORY INFORMATION

Warnings

• 

  The Zip HydroChill

 

 must be earthed. The resistance of the earth connection 

from each exposed metal part must be less than 1Ω.

•  All installation and service work must be completed by trained and suitably 

qualified tradespeople. Faulty operation due to unqualified persons working on 
this product, or any other Zip product may void warranty coverage.

•  As the installer, it is your responsibility to supply (if necessary) and install all 

valves as required by local regulations and relevant standards.

•  The HydroChill is rated for 230V 50Hz AC operation.
•   Do not remove the cover of the appliance under any circumstances without 

first isolating the appliance from the power supply.

•  Never locate the Command Centre near, or clean with water jets.
•  Do not expose the Zip HydroChill

 

 to the elements of nature.

•  Due to the process of continuous improvement, Zip reserves the right to 

change details mentioned in this manual, without notice.

•  Visit www.zipwater.co.uk to ensure you have the latest copy of this document.

!

Содержание HydroChill HC45T128

Страница 1: ...806143UK V1 00July2019 HydroChillHC45 Technicalsupport Tel 03456005005 Email service zipindustries co uk www zipwater co uk Installation instructions usermanual Zip HydroChill HC45Under counterchille...

Страница 2: ...ctions before installing the HydroChill system Installation This system must be installed in accordance with water supply byelaws current IEE regulations and relevant local authority byelaws Electrica...

Страница 3: ...or more do not fill and commission it until ready for first use The HydroChill must be sanitised during the commission process please contact the Zip Water team on 0345 6 005 005 to book your commissi...

Страница 4: ...ressure reducing valve is required to be fitted in the supply line See Accessories below Power Supply 230V AC 13A Chiller type Fan cooled condenser with compressor Operating temperature range 5 C 35 C...

Страница 5: ...14 Overload Compressor Tecumseh THB4422YWZ 5 93703UK Filter 6 94358 Filter Head 45 Deg 7 SP91461 Fan 9 94379 IEC Socket Assy 10 SP93230 Power Switch 11 SP91552 1 2 BSP 1 4 JG Adapator 12 91482 500 KPa...

Страница 6: ...els 1 x 220 240V AC 13A socket will be required The Command Centre must be installed in accordance with IEE regulations See Technical specification page 4 for power ratings Note Check all cable and ho...

Страница 7: ...e of water that can flow through at one time is limited to a pre determined maximum providing the flow rate through it exceeds 2 litres per minute The Water Block also incorporates a non return valve...

Страница 8: ...correct and that the filter screen see Fig 2 is inserted correctly with the convex surface facing towards the water supply 1 1 Installation Fig 2 Fit key to adjust flow Key Reset lever 1 2 Reset Proce...

Страница 9: ...entre installation page 13 When installing air flow vents the following tools will be required Jigsaw and drill or equivalent equipment Keyhole or wall board saw 2 1 Generic requirements Clearance env...

Страница 10: ...in these diagrams The 100mm separation between inlet and outlet vents must be observed to prevent recirculation of warm air back into the cupboard space 2 2 Ventilation for all models The clearance e...

Страница 11: ...he kick board e g hospitals use a Vent tray kit SP93541 Vent tray 100mm min A vent grille supplied should be used as an inlet vent and fitted to the cabinet side adjacent to the Command Centre air inl...

Страница 12: ...asher Washer Lower rubber washer Nut Red white and blue pipes Red white and blue pipes 3 1 Configure the twin lever tap Heavy duty Twin lever 3 2 Cut the hole mount the tap 3 3 Configure the heavy dut...

Страница 13: ...ation valves are not supplied To avoid water leaks be careful not to damage the tap pipes Pipes must not be kinked around a bend If shortening pipes ensure ends are cut clean and square see Push fit f...

Страница 14: ...d water isolation valve not supplied VENT CHILLED OUT 5 2 Manifold connections 5 3 Installation arrangements Connect to Red 1 4 pipe from tap Blue 1 4 pipe from tap via 1 4 push fit connector supplied...

Страница 15: ...WATER IN CHILLED OUT AMBIENT OUT 6 2 Manifold connections 6 3 Installation arrangements Connect to Red 1 4 pipe from tap Connect to Mains Cat 1 Cold water supply Connect to White 1 4 pipe from tap Co...

Страница 16: ...ght remain in the product which requires the products to be flushed with fresh water at installation So the first few glasses of water may look soapy with presence of bubbles As part of the purge proc...

Страница 17: ...to catch and mop up any spills Gently ease the cartridge downwards to detach it from the filter head then pull it out and discard responsibly Take care not to tip it up once free as water may spill ou...

Страница 18: ...rvice work including filter replacements sanitisation electrical safety inspections as well as general maintenance of your HydroTap please visit zipwater co uk HydroCare or contact Zip on 0345 6 005 0...

Страница 19: ...trictly in accordance with the terms and conditions and the instructions supplied with the product and Ii The failure is not due to accident misuse abuse unsuitable water conditions including contamin...

Страница 20: ...instructions usermanual 806143UK V1 00July2019 HydroChillHC45 Technical support Tel 03456005005 Email service zipindustries co uk www zipwater co uk ZipWaterUK 03456005005sales zipindustries co uk www...

Отзывы: