Installation - Section 2 Ventilation
2.4 Alternative arrangement (Vent tray)
In situations where cupboard width is 1000mm or greater, without central pillar and where vent grilles cannot be
fitted in the kick board (e.g. hospitals) use a
Vent tray kit
(SP93541).
Vent tray
100mm
min.
A vent grille, supplied should be used as an inlet vent and fitted to the cabinet side (adjacent to the Command
Centre air inlet) as shown below. It must take in air from the room or another ventilated space. This space could
be an adjacent cupboard, (via a communicating port) on condition that it does not contain a heat generating
appliance. The vent grille or the
angled inlet grille supplied should
be fitted in the adjacent cupboard,
observing 100mm separation from
the vent tray exhaust.