13
Installation instructions & user manual
806143UK V1.00 July 2019 - HydroChill HC45
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
Installation - Section 4 Command Centre installation
4.2 Push fit fittings
4.1 Generic Command Centre installation instructions
Read these instructions before commencing Command Centre installation,
they apply to all installation arrangements.
!
• Install the mains water braided hoses to the Command Centre before locating in place.
• Ambient mains water braided hose length is 750mm.
• Electrical power cable is 1.8m long.
• The Command Centre
must be installed within the limits of
the hose and cable lengths supplied.
• • All plastic pipes must be cut to size. They must have a
All plastic pipes must be cut to size. They must have a
constant fall back to the
constant fall back to the Command Centre.
• • Isolation valves are not supplied.
Isolation valves are not supplied.
• To avoid water leaks, be careful not to damage the tap pipes.
Pipes must not be kinked around a bend.
If shortening pipes, ensure ends are cut clean and square
(see ‘Push fit fittings’ below).
• Before fitting the tap pipes , remove plugs from the outlet
fittings on the top of the Command Centre by pressing the
collet and simultaneously pulling out the plug.
• Measure and trim the red , white and blue 1/4” coloured
pipes from the tap to the outlet fittings on the top of the
Command Centre. (See sections 5-6 page 14-15).
• Before making the connections insulate the hoses with the
loose length of foam insulation supplied. Trim the insulation
to about 5-10mm shorter than the tube.
• For correct connections, refer to :
Section 5 for HydroChill chilled HC45T128
Section 6 for HydroChill chilled ambient HC45T228
• Push each hose into the quick-release connector as far as it
will go (approx. 15 mm) to ensure a tight connection. (see
‘Push fit fittings’ below).
90º bend
Connect to
HydroChill
Braided hose for mains
water supply
Mains cold
water supply
Water block
(optional)
Isolation valve