MS-SOUND-decoders MS440 to MS990 Page 31
ZIMO small-scale decoders have between 4 and 12 function outputs (FO). Consumers connected to
these outputs (lights, smoke generator etc.) are switched ON and OFF with the function keys on the
controller. Which function key controls which function output can be defined with the NMRA function
mapping.
CVs #33 to #46
define the NMRA function mapping. Unfortunately, this function mapping also has its limitations (only
one 8-bit register is available for each function, which leaves only 8 outputs to select from) and only
the headlight function is intended to change with direction.
Fu
nct
io
n k
ey
on
th
e c
on
tro
lle
r
Numeric key
on the
ZIMO
Controller
CV
Function outputs
Function outputs
FO12 FO11 FO10 FO9 FO8 FO7 FO6 FO5 FO4 FO3 FO2 FO1 Rear
light
Front
light
F0
1 (L) fw #33
7
6
5
4
3
2
1 0
⚫
F0
1 (L) re
#34
7
6
5
4
3
2
1
⚫
0
F1
2
#35
7
6
5
4
3
2
⚫
1
0
F2
3
#36
7
6
5
4 3
⚫
2
1
0
F3
4
#37
7
6
5
4
3
2
1
⚫
0
F4
5
#38
7
6
5
4
3
2
⚫
1
0
F5
6
#39
7
6
5
4 3
⚫
2
1
0
F6
7
#40
7
6
5
4
⚫
3
2
1
0
F7
8
#41
7
6
5
4
3
2
⚫
1
0
F8
9
#42
7
6
5
4 3
⚫
2
1
0
F9
0
#43
7
6
5
4
⚫
3
2
1
0
F10
1
#44
7
6 5
⚫
4
3
2
1
0
F11
2
#45
7 6
⚫
5
4
3
2
1
0
F12
3
#46
7
⚫
6
5
4
3
2
1
0
The black dots in the table above indicate the default settings at the time of delivery, where each function
key corresponds to the same numbered function output. Therefore, the following values were written into
these CVs by default:
CV #33 = 1
CV #34 = 2
CV #35 = 4
CV #36 = 8
CV #37 = 2
CV #38 = 4
CV #39 = 8
CV #40 = 16
CV #41 = 4
and so on..
EXAMPLE of a modification to the function mapping: The F2 key (ZIMO #3 key) should switch output
FO4 in addition to output FO2. Moreover, F3 and F4 should NOT switch FO3 and FO4 but rather FO7
and FO8 (couplers, for example). New values are to be entered into the relevant configuration varia-
bles as follows:
CV #36=40
CV #37 = 32
CV #38 = 64
F2
3
#36
7
6
5
⚫
4
3
⚫
2
1
0
F3
4
#37
7
6
5
⚫
4
3
2
1
0
F4
5
#38
7
6
⚫
5
4
3
2
1
0
By
CV #61 = 97
the left shift of higher CVs (#37 and up, according to the original NMRA function mapping) is deac-
tivated, which allows higher function keys to be mapped with lower function outputs: e.g.: “F4 controls
FO1” is not possible with NMRA, but is with ZIMO.
FO6 FO5 FO4 FO3 FO2 FO1 Headlights
rear front
F0
1 (L) for.
#33
7
6
5
7
6
5
7
6
5
7
6
5
4
3
2
6
5
4
3
⚫
2
7
6
5
4
⚫
3
2
7
6
5
⚫
7
6
5
4
3
2
1 0
⚫
F0
1 (L) rev
#34
7
6
5
4
3
2 1
⚫
0
F1
2
#35
7
6
5
4
3 2
⚫
1
0
F2
3
#36
7
6
5
4 3
⚫
2
1
0
F3
4
#37
7
6
5 4
⚫
3
7
6
5
2
1
0
F4
5
#38
7
6
5
⚫
4
3
2
1
0
F5
6
#39
7 6
⚫
5 4
3
2
1
0
F6
7
#40
7
⚫
6 5 4
3
2
1
0
F7
8
#41
7
6 5 4
3
2
1
0
F8
9
#42
7
6 5 4
3
2
1
0
F9
0
#43
7
6 5 4
3
2
1
0
F10
1
#44
7
6 5 4
3
2
1
0
F11
2
#45
7
6 5 4
3
2
1
0
F12
3
#46
7
6 5 4
3
2
1
0