15
Name
LED state
Status
Measure
Status 1/2 (IO-Link device)
off
• No supply voltage
►
Restart the SCM.
►
Please contact Zimmer
Customer Service.
Continuous light
• An error is present
►
Connect the supply
voltage.
Flashing
• IO-Link device is discon-
nected.
►
Check the IO-Link device.
2x flashing
• SCM starts with high
SCM input.
• IO-Link device switches
with high SCM input.
►
Establish a connection to
the IO-Link device.
3x flashing
• Workpiece invalid for
connected IO-Link device.
•
No workpiece defined.
►
Set the SCM input = 0.
4x flashing
• IO-Link device not
recognized.
►
Select a valid workpiece.
►
Teach the workpiece.
5x flashing
• Communication error
►
Restart the SCM.
►
Please contact Zimmer
Customer Service.
6x flashing
• Communication error
►
Restart the SCM.
►
Please contact Zimmer
Customer Service.
Flashing
• Unknown IO-Link device -
Continuous light
• Gripper in end position or
no taught-in part gripped.
-
Continuous light
• Taught-in workpiece
gripped
-
Continuous light
• IO-Link device moving
-
Continuous light
• IO-Link device at
UndefinedPosition
-
(P 24 V)
Continuous light
• Actuator voltage OK
-
off
• Actuator voltage not OK
►
Use a compatible IO-Link
device.
INSTALLATION AND OPERATING INSTRUCTIONS:
LWR50F-01-03-A
DDOC01360 / -
EN / 2022-05-09
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com