INSTALLATION AND OPERATING INSTRUCTIONS:
O-ring assembly gripper, pneumatic, GS series
7
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
EN / 2020-11-30
DDOC00228 / g
7 Installation
7.1 General installation information
WARNING
Risk of injury in case of unexpected movement of the machine or system into which the product is to be installed.
►
Switch off the power supply to the machine before all work.
►
Secure the machine against being switched on unintentionally.
►
Check the machine for any residual energy.
CAUTION
Risk of injury in the event of unexpected movement of the product when the power supply is connected.
►
Switch off the power supply to the product before all work.
►
Secure the power supply against being switched on unintentionally.
►
Check the product for any residual energy.
NOTICE
Switch off the power supply before any assembly, installation or maintenance work.
The product must be installed on a suitable mounting surface in accordance with the flatness specifications.
Ö
Permissible unevenness: 0.03
• The mounting screws are not included in the scope of delivery.
•
Strength class of the mounting screws: ≥ 8.8 (DIN EN ISO 4762)
►
Observe the tightening torque of the mounting screws.
Ö
Zimmer GmbH recommends verifying the permitted load-carrying capacity of the required screw connections in
accordance with VDI 2230.
►
The exact installation positions can be found on the technical data sheet on our website.