39
11.4 TIA Portal
NOTICE
This section uses the commissioning of the product of the GEH8660-B installation size as an example project.
The example project is intended as an aid and must not be used as a programming template.
Commissioning the product depends on the configuration of the drive control unit and can therefore vary.
11.4.1
Configuring the drive control unit
►
Connect the drive control unit to the computer using its network interface.
►
Search for the correct drive control unit using the
IndraWorks Ds
software, see section “Setting the IP address”.
Ö
The connection to the drive control unit is established.
►
In the
Configuration
menu, click
Load
.
Ö
The
Load Parameters
window opens.
►
Enable the option field of the desired parameter set.
►
Click the
Load
button.
Ö
The
Load Parameters
window closes.
►
In the navigation pane, click
Master
Communication
.
Ö
The
Master Communication Basic Settings
tab is displayed in the window.
►
Click the
Engineering via IP (X24/X25)
tab.
►
Enter the IP address for configuring the drive control unit.
INSTALLATION AND OPERATING INSTRUCTIONS:
GEH8000
DDOC00262 / e
EN / 2023-03-06
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com