11 Commissioning
11.1 Checking operational readiness
►
Check the energy supply.
►
Check all mounting screws for the prescribed tightening torque.
11.2 Easy Startup
11.2.1 Setting the IP address
►
Define the IP address for the drive control unit.
• Standard: 192.168.0.1
►
Enable the IP range on your computer for the entry of the IP address in the drive control unit via the control panel.
►
Press the
Enter
button.
►
Navigate by pressing the
buttons.
►
Navigate to the
Ethernet
entry.
►
Press the
Enter
button.
Ö
The selection has been confirmed.
►
Press the
Enter
button.
Ö
The
IP-Addr
entry is shown.
►
Set the IP address by pressing the
button.
►
Press the
Enter
button.
Ö
The input has been confirmed.
►
Restart the drive control unit.
INFORMATION
The software
IndraWorks Ds
or
IndraWorks Engineering
is required for initial commissioning.
This setting can vary in other software versions.
►
Please consult the software manufacturer to learn how to use the software version available to you.
Ö
Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole
responsibility.
►
Start the
IndraWorks Ds
software.
►
Enter the IP address in the
IndraWorks Ds
software and the computer.
►
Click the
Search
button.
Ö
Found drive control units are shown in the
Connection Selection
window.
►
In the
Connect
column, enable the option
field of the desired drive control unit.
• The IP address of the drive control unit
must match.
►
Click the
OK
button.
Ö
The connection to the drive control unit is
established.
Ö
The main window of the
IndraWorks Ds
software opens after successful connection.