11.3 EtherCAT
NOTICE
Commissioning the product depends on the configuration of the drive control unit and can therefore vary.
This section uses the commissioning of the product of the GEH8660-B installation size as an example.
►
Do not use the example as a programming template.
►
For more information, refer to the "Function of the function block” section.
11.3.1
Configuring the drive control unit
►
Connect the drive control unit to the computer using its network interface.
►
Search for the correct drive control unit using the
IndraWorks Ds
software, see section “Setting the IP address”.
►
In the
Configuration
menu, click
Load
.
Ö
The
Load Parameters
window opens.
►
Enable the option field of the desired
parameter set.
►
Click the
Load
button.
Ö
The
Load Parameters
window closes.
►
In the navigation pane, click
Master
Communication
.
Ö
The
Master Communication Basic Settings
tab is displayed in the window.
►
In the
Active Protocol
drop-down menu,
select the communication type for the
control system.