29
11.3.3.2 Setting the drive control unit
►
Click the example project in the
Solution
Explorer
.
►
Click
I/O
.
►
Click
Devices
.
►
Click
Device 5 (EtherCAT)
.
►
Click
Device 1 (IndraDrive)
.
Ö
The window of the example project opens.
►
Click the
EtherCAT
tab.
►
Click the
Advanced Settings
button.
Ö
The
Advanced Settings
window opens.
►
Click
Mailbox
.
►
Click
EOE
.
►
Activate the
Visual Ethernet Port
option field.
►
Activate the
IP Address
option field.
►
Enter the desired IP address in the
IP
Address
field.
►
Enter the desired subnet mask in the
Subnet
Mask
field.
• Example: 255.255.255.0
►
Enter the IP address of the EtherCAT master
in the
Default Gateway
field.
►
Enter the desired DNS name in the
DNS
Name
field.
• The DNS name can be selected as
desired.
INFORMATION
In the example, the network card of Port X001 of the CX control system is entered under Windows.
►