background image

Z8 Encore! XP F042A 8-Pin Development Kit

Quick Start Guide

QS005506-0111

Page 13 of 15

You can also use the Z8 Encore! XP F042A Series 8-pin Development Kit 
and its sample project to evaluate the development environment for the Z8 
Encore! XP F08xA and F0823 Series 8-pin MCUs. The Z8 Encore! XP 
Series 8-pin development board may also be used with a ZDS II project that 
targets the Z8 Encore! XP F08xA or F0823 8-pin devices. However, the 
device’s feature limitations, such as reduced program space, will exist. The 
Z8 Encore! XP F042A 8-pin device on the development board may also be 
replaced with a Z8 Encore! XP F08xA or F0823 8-pin device for a more 
detailed chip evaluation.

Troubleshooting Tips

If you experience trouble running the demo program with the Z8 Encore! XP development 
board, check the following before contacting Zilog Technical Support for assistance:

Verify that you are using ZDS II version 5.0.0 or later. 

Ensure that you are using the unmodified sample project code as described in 

Getting 

Started Using ZDS II

 on page 8. 

Verify that you have properly connected the USB Smart Cable to the host PC and the 
8-pin development board as described in 

Setting Up the Development Board

 on page 

3. Ensure that pin 1 of the cable is properly aligned with DBG connector pin 1 of the 
development board.

Apply power to the development board using S2 slide switch. The green 3.3 V DC 
LED should be ON. If it is not illuminated, verify if power is properly connected to 
the board as described in 

Configuring the 5 V DC Universal Power Supply

 on page 2.

In ZDS II, verify select the 

Project 

 Settings 

 Debugger 

 Communication

 

menu item and verify that the serial number for the USB Smart Cable interface is pres-
ent and selected. If the serial number is missing, reinstall the USB Smart Cable driver 

software.

In ZDS II, verify that 

Z8F04A08100KITG

 is selected as the target.

In ZDS II, click the 

Rebuild All

 

 button. Verify that the project rebuilds with no 

errors.

Verify that the development board is not currently running any code – no LEDs should 
be blinking.

In ZDS II, click the 

IDE Reset

 

 button. ZDS II will connect to the development 

board and download code to it.

Note:

Содержание Z8 Encore! XP

Страница 1: ...for connecting the PC to Z8 Encore XP F042A Series Develop ment Board 5V DC Universal Power Supply Software on CD ROM Software requirements include Zilog Developer Studio II Zilog Developer Studio II...

Страница 2: ...ew plug adapter into the slot until it snaps into place Table 1 Zilog Developer Studio II System Requirements Recommended Configuration Minimum Configuration Windows XP Professional SP3 or later Penti...

Страница 3: ...d of the power supply and an electrical outlet Setting Up the Development Board The USB Smart Cable connects the target Z8 Encore XP development board to a high speed or full speed USB port on your ZD...

Страница 4: ...dalone Demo mode ensure that the jumpers are set as follows J3 1 2 J4 OUT J5 1 2 J6 1 2 J7 OUT J8 1 2 J9 1 2 J10 1 2 J11 OUT To run the kit in DEBUG mode follow the steps as described in Getting Start...

Страница 5: ...ersions of Windows 7 ZDS II Installation Directory device drivers USB x64 ZDS II Installation CD device drivers USB x64 6 Click Next The Windows Security dialog box appears 7 Select Install this drive...

Страница 6: ...dware Wizard should activate automatically after connecting the Zilog USB device for the first time select No not at this time if asked to connect to Windows Update 2 Select Install from a list or spe...

Страница 7: ...ribbon cable included to the USB Smart Cable six pin DBG connector as displayed in Figure 2 Attach the free end of the ribbon cable to the DBG connector on the target board Ensure that pin 1 on the r...

Страница 8: ...drive and double click the launch exe file to launch the installer 2 DemoShield provides several installation options Select Install Zilog Developer Stu dio to install now You can install other softw...

Страница 9: ...elopment Board on page 3 Do not apply power to the development board unless the USB Smart Cable is connected both to the host PC and to the development board s DBG port P3 3 Run the Zilog Developer St...

Страница 10: ...04XP_8Pin_ledBlink src 6 Select the ledblink zdsproj file and click Open The initial Zilog Developer Stu dio II program screen appears see Figure 3 If you want to view the project source files double...

Страница 11: ...en using the USB Smart Cable Click F1 for additional information on how to setup the debugger 8 Click OK 9 Click the Rebuild All icon to build the project Wait for the build to complete as indicated b...

Страница 12: ...p 3 LED D2 PA0 is shared with the DBG pin Zilog does not recommend having the LED connected while connecting to the target or while in debug mode J3 should be OUT 13 Press the TEST push button to chan...

Страница 13: ...code as described in Getting Started Using ZDSII on page 8 Verify that you have properly connected the USB Smart Cable to the host PC and the 8 pin development board as described in Setting Up the Dev...

Страница 14: ...our host PC and console port P2 of the development board Set the communication settings in HyperTerminal to 57600 baud 8 bits no parity and one stop bit These settings are also noted in the main c fil...

Страница 15: ...ailure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2011 Zilog Inc All rights reserved I...

Отзывы: