8
All information contained herein is the exclusive copyright of Round Bank Engineering Ltd and is not to by copied,
duplicated or otherwise distributed without the express permission of Round Bank Engineering Ltd, Unit 7, Victoria
Business Park, Halifax, UK, HX1 5ND - +44 (0) 1422 647177
–
UART Control
The UART connections are used to set up all the required user-settable parameters.
Please note that all parameters will be stored in EEPROM, this means that they are non-volatile and
the controller will remember these settings when the power is disconnected.
Zikodrive will provide an
“ini”
(Config) file that can be uploaded into ZDA software that can be used
to modify settings and parameters to suit the required application.
These “ini”
(Config) files can be
modified and saved for each of the application requirements using ZDA. The standard version of this
file is available for download from
Using the UART
The UART communication can be operated from any serial terminal program or microcontroller. If
you have a specific requirement for this or require any assistance please contact us directly and we
can advise on how best to achieve your requirements.
UART COM Port settings for the ZDBL30MUL-48:
Baud Rate: 115200, Data bits = 8, Parity = None, Stop bits = 0.