Output Setting
A settable output value that can be changed depending on what the requirements are:
Output 1 Value
Condition
0
Always off (low)
1
High on Fault
2
High on commutation
3
High every electric Frequency
4
Motor running
5
Always High
Bemf Data
This command is used for validating the BEMF data. Please contact Zikodrive for further information.
Data Export Time (ms)
This command is used for setting a time period for exporting data to a serial plot for analysis or data
recording. Please contact Zikodrive for more information.
Drive Data Items
Data Item Number
Details
0
Drive State
–
Waitinit, Forced, Running, WaitStop, StopDel, Stopped,
Disable, Fault, FaultWaitReset.
1
DriveRunState
–
CheckRun1, CheckRun2
2
FaultCode
3
FaultData
4
PWMDutyCycle (Raw PWM value, not %)
5
MINDuty (Raw PWM value, not %)
6
MAXDuty (Raw PWM value, not %)
7
Zero Crossing Value
8
Phase U Value
9
Phave V Value
10
Phase W Value
11
StepCount
12
Motor Frequency (Hz)
13
Start Attempts
14
RunStepCount
15
Phase Current Raw
16
Max Current (Ax10)
17
Current (Ax10)
18
Power (W)