All information contained herein is the exclusive copyright of Round Bank Engineering Ltd and is not to by copied,
duplicated or otherwise distributed without the express permission of Round Bank Engineering Ltd, Unit 7, Victoria
Business Park, Halifax, UK, HX1 5ND - +44 (0) 1422 647177
–
General Commands
Command Description
Command String
Result meaning
Read/Write?
Application Name
ZDVERSTR\r
ZDVERSTR = ZDBL30MUL-48\r
Version = ZDBL30MUL-48
Read Only
Application Version
ZDVER\r
ZDVER = 100\r
Version 1.00
Read Only
Application Build
Number
ZDVERBN\r
ZDVERBN = 1000\r
Build number = 1000
Read Only
Reset
ZDreset\r
N/A, no reply
Write Only,
no reply
Supply Voltage (Vx10)
ZDvsup\r
ZDvsup = 200\r
Supply Voltage = 20V
Read Only
Motor I (Ax10)
ZDimot\r
ZDimot = 3\r
Motor Current = 0.3A
Read only
Motor Power (W)
ZDpmot\r
ZDpmot = 3\r
Motor Power = 3W
Read only
Controller Temp.
(degC)
ZDctemp\r
ZDctemp = 24\r
Controller Temp = 24 degC
Read Only
Analogue Value
ZDanip\r
ZDanip = 150\r
Analogue Value = 150
Read Only
Pot Value
ZDpotv\r
ZDpotv = 150\r
Pot Value = 150
Read only
Enable Input Value
ZDdinp1\r
ZDdinp1 = 1\r
Enable Input Value = 1
Read Only
Enable Dir Value
ZDdinp2\r
ZDdinp2 = 1\r
Enable Dir Value = 1
Read Only