13
Function extension and version of software
Display version
menu group Start under Fcontrol
Version
Date
Function from new version
11.12
22.05.2014
First edition
14
Enclosure
14.1
Technical data
Type
Part-No.
Rated cur-
rent
Output
{1}
[A]
Rated cur-
rent
(
I
fundamen-
tal compo-
nent @
50 Hz)
Input
{2}
[A]
Rated tem-
perature
[
°
C]
max. line
fuse
{3}
[A]
Max. heat
dissipation
approx.
{2}
[W]
Noise ap-
prox.
{4}
[dB]
Weight
[kg]
FXDM25AM
308289
25
22.8 (20.1)
55
35
550
-
21.5
FXDM32AM
308283
32
27.6 (25.7)
50
35
700
-
23.1
1
Rated current output
current indication rating plate @ rated voltage, @ rated temperature (cos
φ
0.8 at the output)
2
At rated voltage (cos
φ
0.8 at the output), values for different speci
fi
cations on request.
3
Max. line fuse on site (line protection fuse) according to EN 60204-1 Classi
fi
cation VDE0113 Part 1
4
Acoustic power (A-weighted) by built-in fan
-
Not yet speci
fi
ed
Line voltage*
3 ~ 208...480 V (-15 ... +10 %), 50/60 Hz
Rated voltage
400 V
Maximal output voltage
95 % of U
Line
Maximal output frequency
150 Hz
Power factor
> 0.9
Switching frequency
16 kHz
Input resistance for sensor or signal
set for the rotational speed
for 0 - 10 V input: R
i
> 100 k
Ω
for 4 - 20 mA input: R
i
= 100
Ω
Voltage supply e.g. for sensors
+24 V
±
20 %, I
max
120 mA
Output (0 - 10 V)
I
max
10 mA (short-circuit-proof)
Digital inputs
“
D1
”
and
“
D2
”
Input resistance: R
i
approx. 2 k
Ω
Voltage range high level: 10....30 V DC
Voltage range low level: 0....4 V DC
Max. contact rating of the internal relay 2 A / 250 V AC
Max. permissible ambient temperature
for operation
55
°
C
Min. permissible ambient temperature
for operation
0
°
C (if mains voltage is not switched off up to -20
°
C)
To avoid condensation the device must be continuously energized due to the applica-
tion of heat, with interruptions such that cooling to the point of condensation does not
occur.
Permissible temperature range for
storage and transport
-30...+80
°
C
Max. permissible installation height
0..4000 m amsl
above 1000 m amsl the rated current is to be reduced by 5 % / 1000 m
Permissible rel. humidity
85 % no condensation
Electromagnetic compatibility for the
standard voltage 230 / 400 V accord-
ing to DIN IEC 60038
Interference emission EN 61000-6-3 (domestic household applications)
Interference immunity EN 61000-6-2 (industrial applications)
Operating Instructions
Fcontrol
–
model series FXDM25/32AM
Function extension and version of software
L-BAL-E212-GB 1451 Index 003
Part.-No.
118/123