5.3
Version without connection cables
ECblue BASIC connection version example
1
Cover of controller housing
2
Version with cable glands 3 x M20x1.5
inserted: 1 x Black seal insert for cables with 8...12 mm outer diameter
inserted: 2 x Blue seal insert for cables with 6...7.9 mm outer diameter
optional: 2 x Black seal insert for cables with 8...12 mm outer diameter
optional: 1 x Blue seal insert for cables with 6...7.9 mm outer diameter
optional: 1x Seal insert with 2 boreholes (6 mm) for two cables
3
Version with cable glands 3 x M16x1.5
inserted: 3 x Seal insert for cables with 4...10 mm outer diameter
optional: 1 x Seal insert with 2 boreholes (5 mm) for two cables
4
Status LED
5
Connection control system
6
Cable entry points with plastic fastener
7
Connection Relays
8
Voltage supply
9
Slot for AM auxiliary module (
“
add-on
”
module function)
10
Slot for AM-STICK-WB
Procedure:
1. Remove the cover from the controller housing for the connection.
2. All 3 cable entry points are in a sealed condition at delivery. Remove plastic fastener if necessary,
and insert enclosed cable glands, entry points that are not used must remain sealed!
3. Insert and connect lines correctly (note the respective connection diagram).
4. Attach cover of controller housing again carefully in correct position before start-up.
Attention!
The seal of the end cap can adopt the contour of the stator
bushing in time.
Therefore mount the cover on the same motor that it was re-
moved from to achieve maximum tightness.
Do not mix the covers!
Attention!
•
Temperatures up to 80
°
C can be present on the controller housing.
•
To connect, always use heat resistant wires or, as an alternative, silicon tubes.
•
Only use lines which can guarantee a permanent seal around the cable glands (pressure-resistant,
dimensionally-stable, round-centred jacket; e.g. by means of gusset
fi
lling)! Lines with
fi
lling
fl
eece
are not permissible because moisture can penetrate due to the capillary effect!
•
Make absolutely sure that different connections do not come into contact (e.g. by splaying or loose
connecting wires).
Assembly instructions
ECblue BASIC-MODBUS, ECblue BASIC
Electrical installation
L-BAL-F079D-GB 2044 Index 002
Part.-No.
23/80