5. Counter/Timers
40
The six programmable operating modes are summarized in the "Counter/Timer
Operating Modes" table following.
Counter/Timer Operating Modes
Mode
Counter/Timer Output Operation
0
Transitions after programmed count expires
Gate tied high to enable counting
1
Transitions after programmed count expires
Gate tied high to enable counting
2
Periodic single pulse after programmed count expires
Gate tied high to enable counting
3
Square wave with frequency equal to programmed count
Gate tied high to enable counting
4
Single pulse after programmed count expires
Gate tied high to enable counting
5
Single pulse after programmed count expires
Gate tied high to enable counting