Configurable Options
For 8-bit I/O addresses, remove Jumper W6 to inhibit the upper 8 bits
of address. For 16-bit I/O addresses, Jumper W6 must be IN. Only
bits 15-12 and 7-4 may be changed in the I/O base address (see Table
5-7). Bits 11-8 are hardwired to 1110 (0Eh), and bit 3 is hardwired to
logical 1. Bits 2-0 are used to decode the various registers on the
ZT 8825. Jumpers W14-11 are used to set address bits 15-12, and
Jumpers W10-7 are used to set address bits 7-4. If the jumper is OUT,
the corresponding address bit must be a logical 1 in the base address
to access the board. Similarly, if the jumper is IN, the address bit must
be a logical 0.
Table 5-7
Jumpers for I/O Base Address Decoding.
I/O Address bits
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
W14
W13
W12
W11
1
1
1
0
W10
W9
W8
W7
1
Register
Number
The default I/O base address on the ZT 8825 is 0EE68h