Getting Started
I/O ADDRESSING
The ZT 8825 has four I/O registers that are used to configure the
board (see Table 2-5. These registers require jumpers to set the base
I/O address (see Table 2-6 on page 2-17). The default base address is
0EE68h.
Table 2-5
ZT 8825 I/O Registers.
Base+
Default
Description
000
EE68h
Low order six bits of map register
address (write only)
001
EE69h
High order four bits of map register
address (write only)
010
EE6Ah
Data to/from map register previously
addressed (read/write)
011
EE6Bh
Configuration register (write only, reset
to 0 at power-on)
2-16