Installation
30
025-9459E
Figure 5. Location of Jumpers in the Radio Interface
Remote Configuration
Configuring the remote consists of setting jumpers inside the product if necessary. The
installer configurable jumpers and their functions are described in
.
shows the locations of the jumpers on the remote main PCB.
Table 2. Configuration Jumpers on the Remote Main PCB (702-0007)
Jumper
Purpose
Positions
JP3 Supervisor
This jumper sets the remote as a supervisor or non-
supervisor. Supervisor remotes are not affected when
privacy mode is initiated by users at other remotes.
Furthermore, when a Supervisor remote initiates privacy
mode, it will not time out.
A - Not a Supervisor
B - Supervisor
JP4
Adjacent Deskset Muting
If this feature is enabled, the front panel speaker of the
remote will be muted when another remote is
transmitting. If multiple remotes are located in the same
room, enabling this feature prevents feedback.
A - Muting Disabled
B - Muting Enabled
JP6 Handset/Headset
Earpiece
This jumper sets earpiece audio gain to the proper level
for either the handset or a headset.
A - Handset
B - Headset
JP7 Handset/Headset
Mouthpiece
This jumper sets mouthpiece audio gain to the proper
level for either the handset or a headset.
A - Handset
B - Headset
Содержание 360
Страница 1: ...Model 360 Radio Remote Instruction Manual for Kenwood Radios 025 9459E ...
Страница 8: ...Model 360 Radio Remote 8 025 9459E ...
Страница 54: ...Programming 54 025 9459E ...
Страница 69: ...Assembly Drawings 69 ...
Страница 70: ...Troubleshooting and Repair 70 025 9459E ...
Страница 74: ...Specifications 74 025 9459E ...